Dell EMC VxRail: Physical view not working after a code upgrade
Summary: After a successful code upgrade, the physical view stopped working.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
VxRail Manager's physical view does not load any information after a successful upgrade.
web.log:
web.log:
2022-04-29 17:06:47.787+0000 ERROR [pool-17-thread-1] com.emc.mystic.manager.cluster.service.ApplianceServiceImpl ApplianceServiceImpl.buildPvNodes:677 - failed to fetch data.
java.lang.IllegalStateException: Duplicate key vmk2 (attempted merging values MANAGEMENT and VMOTION)
at java.util.stream.Collectors.duplicateKeyException(Collectors.java:133) ~[?:?]
Cause
All hosts had the vMotion traffic that is enabled on vmk2.
[root@esx-01:~] esxcli network ip interface tag get -i vmk2 Tags: Management, VMotion
Customers may do this to perform cross-cluster/cross-vCenter vMotion, taking advantage of the available routing the Management vmkernel provides.
vMotion has to be enabled on its dedicated interface (Dell vmk4/Quanta vmk3).
Resolution
To resolve this issue, remove vMotion from vmk2 and assign it to a dedicated interface.
Affected Products
VxRail Appliance Family, VxRail Appliance SeriesArticle Properties