Avamar: Gen4T warning disk firmware does not match the latest known version in proactive check
Summary: This article shows how to resolve the warning disk firmware in a proactive check script.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Note: Customers are not expected to install this Hotfix, the Support team can help in installing this Hotfix.
Use this article to run the proactive health check: Avamar: How to Run the proactive_check.pl health check script on an Avamar Server
When a proactive check is run on an Avamar Gen4T system, a warning message related to disk firmware is shown:
WARNING: Node 0.0 Disk 9 Firmware N9C0 does not match the latest known version of NAM4 WARNING: Node 0.0 Disk 10 Firmware N9C0 does not match the latest known version of NAM4 WARNING: Node 0.0 Disk 4 Firmware N9C0 does not match the latest known version of NAM4 WARNING: Node 0.0 Disk 11 Firmware N9C0 does not match the latest known version of NAM4 WARNING: Node 0.0 Disk 5 Firmware N9C0 does not match the latest known version of NAM4 RESOLUTION: See hotfix 299999 for more information
The firmware must be updated at the earliest opportunity. Since this hotfix can be installed on a running system, no downtime is required. Install the hotfix when the system is idle.
The hotfix must not be applied to systems that do not include Avamar Data Store (ADS) Gen4T hardware.
Example:
- Systems based on Gen3, Gen4, Gen4S, or Gen5A hardware.
- Virtual Machine systems, example: AVE, VDP, or VDPA.
Steps to install hotfix.
1. Run the proactive health check.
2. Ensure that at least one checkpoint was created and validated within the past 24 hours.
3. Ensure that replication to another server has succeeded within the past 24 hours.
4. Remedy errors in the system log files, particularly those related to hard disk storage.
5. Remedy unacknowledged server-related events in the Avamar Management Console Server (MCS).
The script checks if all the logical drives are "Optimal". If the logical drives are not all Optimal, then the script stop with an error message. It must correct the underlying cause before attempting to run this script again.
Download the ads4t_hgst_update.tgz from hotfix 299999 using this article: Avamar: How to find and download a product hotfix, patch, install or upgrade package from the Dell Support website..
SINGLE-NODE UPDATE:
As root, copy the ads4t_hgst_update.tgz file to the /tmp directory on the system to be updated.
Enter the /tmp directory and unpack the tar file with these commands:
cd /tmp tar xvfz ads4t_hgst_update.tgz
Enter the update directory with the command:
cd ads4t_hgst_update
Run the update script with the command:
./ads4t_hgst_fwupdate.sh
The script examines the drives and updates only the Hitachi 2TB SAS Aries-KP drives. A reboot is not required. If any update fails re-run the script until "Nothing to do" is reported.
MULTI-NODE GRID UPDATE:
Log in to the Avamar Utility Node as admin, switch to root and load the keys:
su - ssh-agent bash ssh-add /root/.ssh/rootid
Copy the ads4t_hgst_update.tgz file to the /tmp directory on the Avamar Utility Node. Propagate the ads4t_hgst_update.tgz file to all the nodes with the commands:
cd /tmp mapall --noerror --all+ --user=root copy ads4t_hgst_update.tgz mapall --noerror --all+ --user=root 'mv ~root/ads4t_hgst_update.tgz /tmp/'
Extract the script and run it with the commands:
mapall --noerror --all+ --user=root 'cd /tmp ; tar xvfz ads4t_hgst_update.tgz' mapall --noerror --all+ --user=root 'cd /tmp/ads4t_hgst_update ; ./ads4t_hgst_fwupdate.sh'
The script examines the drives and update only the Hitachi 2TB SAS Aries-KP drives.
Note: No reboot is required.
If any update fails, re-run the script until "Nothing to do" is reported for all nodes. Updating takes about 30 s per drive.
Affected Products
Avamar Data Store Gen4TProducts
Avamar, Avamar ServerArticle Properties
Article Number: 000202074
Article Type: How To
Last Modified: 31 May 2024
Version: 9
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.