Data Domain: Alert - IO module has failed | ENVIRONMENT-00029

Summary: When an I/O Module (aka SLIC or PCI card) fails or is removed from a Data Domain (DD), the system generates the EventID: ENVIRONMENT-00029: Event Message: I/O module has failed.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The failure or removal of an I/O card (e.g SAS, NIC, NVRAM, FC) results in loss of communication to the affected card. 
Hot-Swap of PCIe devices is NOT supported.

Note: Hot-swap triggers an unexpected reboot of the system.

Alert Example:

Alert Id:       147
Event Id:       EVT-ENVIRONMENT-00029
Event Message:  I/O module has failed
Object:         Enclosure=1:Slot=7
Additional Information: Cause=A hardware fault occurred

This KB applies to PCIe devices; the same alert can also be generated against a Trusted Platform Module (TPM)

Cause

The failure or removal of a system module (I/O card)

Resolution

Check and confirm the status of the affected card:

  • DDCLI (SSH) # system show hardware
    • A failed or removed card slot reported as '(empty)' 
    • Example:
      sysadmin@DD# sys show hardware
      Slot   Vendor   Device                            Ports
      ----   ------   -------------------------------   --------------
      M      QLogic   QL41000 4x 10GBase-T (NDC)        Ma, Mb, Mc, Md
      1      QLogic   QL41164 4x 10GbE SFP+             1a, 1b, 1c, 1d
      2      EMC      NVRAM 16GB Card
      3      EMC      PMC Quad Port 12 Gbps SAS         3a, 3b, 3c, 3d
      4      Intel    Intel QuickAssist Adapter 8970
      5      EMC      Quad Port 16 Gbps Fibre Channel   5a, 5b, 5c, 5d
      6      QLogic   QL41000 2x 25GbE                  6a, 6b
      7      (empty)         (empty)
      8      QLogic   QL41000 2x 25GbE                  8a, 8b
      ----   ------   -------------------------------   --------------

       

      • This example show slot 7 as (empty) as the card in that slot had failed.
    • This output can be compared to Auto-Support to determine the missing card if all slots are not populated.

If the card was removed accidentally:

  • Power off the DD unit, DDCLI (SSH): 
    • # system poweroff
  • Reinstall the card as needed
  • Power the system back on.

If the card is suspected to be faulty or failed, contact your Support Provider to investigate and arrange a repair or replacement.

Affected Products

Data Domain, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection Hardware
Article Properties
Article Number: 000203868
Article Type: Solution
Last Modified: 29 Sep 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.