VxRail: Identify a failed disks physical slot from ESXi CLI

Summary: Identify a failed disks physical slot from ESXi CLI.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

  1. Log in to the ESXi host using SSH.
  2. List vSAN disks using this command:
    esxcli vsan storage list
  3. Examine the output. One of the devices does not have any associated UUIDs and the on-disk format version will be reported as <Unknown>:
    For example:
    naa.6000c29c53fc02afe598901871729854
    Device: naa.6000c29c53fc02afe598901871729854
    Display Name: naa.6000c29c53fc02afe598901871729854
    Is SSD: false
    VSAN UUID:
    VSAN Disk Group UUID:
    VSAN Disk Group Name:
    Used by this host: false
    In CMMDS: false
    On-disk format version: <Unknown>
    Deduplication: false
    Compression: false
    Checksum:
    Checksum OK: false
    Is Capacity Tier: false
    
  4. To identify the failed disk physical slot. From the ESXi SSH, run these commands:

    # esxcli storage core device physical get -d <naa iddentifier device>
    # esxcli storage core device raid list -d <naa iddentifier device>
    The command and example output is:
      
    # esxcli storage core device physical get -d naa.6000c29c53fc02afe598901871729854
     Physical Location: enclosure 2, slot 5
    	
    	Or 
      
    # esxcli storage core device raid list -d naa.6000c29c53fc02afe598901871729854
     Physical Location: enclosure 2, slot 5
    


     

 

Affected Products

VxRail 460 and 470 Nodes, VxRail Appliance Family, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660 , VxRail E660F, VxRail E660N, VxRail E665, VxRail E665F, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4000R, VxRail VD-4000W, VxRail VD-4000Z, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VP-760, VxRail VP-7625, VxRail VS-760 ...