Known issues, environmental and system requirements, and installation or update considerations associated with these patch releases are the same as the parent release. For more information, see the Dell PowerProtect DDOS, DD Virtual Edition (DDVE), DD Management Center (DDMC), DD BoostFS, and DD Boost for OpenStorage 7.10.0.0 to 7.10.1.70 Release Notes.
Release Revision History
| Release |
Description |
| 7.10.1.80 |
- Initial release of 7.10.1.80 (October 2025)
|
| 7.10.1.70 |
- Initial release of 7.10.1.70 (July 2025)
|
| 7.10.1.60 |
- Initial release of 7.10.1.60 (April 2025)
|
| 7.10.1.50 |
- Initial release of 7.10.1.50 (January 2025)
|
| 7.10.1.40 |
- Initial release of 7.10.1.40 (September 2024)
|
| 7.10.1.30 |
- Initial release of 7.10.1.30 (June 2024)
- Correction: ESE Connectivity Telemetry and SupportAssist are not supported in the 7.9.x or 7.10.x releases.
|
| 7.10.1.20 |
- Initial release of 7.10.1.20 (February 2024)
|
| 7.10.1.15 |
- Initial release of 7.10.1.15 (December 2023)
- See DSA-2023-412 for security updates for this release.
- SE Mode has been deprecated.
- See this information before planning a DDOS update:
|
| 7.10.1.10 |
- Initial release of 7.10.1.10 (October 2023)
|
| 7.10.1.1 |
- Initial release of 7.10.1.1 (June 2023)
|
| 7.10.1.0 |
- Initial release of 7.10.1.0 (April 2023)
|
7.10.1.80 Release (October 2025)
Associated Build Versions
- DDOS Build: 7.10.1.80-1198417
- DDVE Build: 7.10.1.80-1198417
- DDMC Build: 7.10.1.80-1198417
- BoostFS Build: 7.10.1.80-1188576
DDOS File System
| Fixed Issue |
Description |
|
DDOSCFD-27191 |
Fixed an issue where the active tier was set to read-only mode despite having available space due to the cloud tier reaching its threshold. |
|
DDOSCFD-27532 |
Fixed an issue where a filesystem panic occurred due to running out of memory in the cache element pool. |
DDOS Platform
| Fixed Issue |
Description |
|
DDOSCFD-23041 |
Resolved a boot issue on DD3300 after upgrade or reboot. |
DDOS Network
| Fixed Issue |
Description |
|
PDD05D-553 |
Fixed an issue where CIFS Server objects were being dropped from Active Directory due to prolonged inactivity. |
DDOS Security
| Fixed Issue |
Description |
|
DDOSCFD-25359 |
Fixed an issue where the value for the Subject-Alt-Name field was getting truncated due to character limit constraint. |
|
DDOSCFD-27661 |
Fixed an issue where backup failures occurred due to Data Domain Boost Avamar certificate issues. |
|
PDD09I-369 |
Fixed a command injection vulnerability that could be exploited by an authenticated attacker. |
Known Issues
| Issue |
Problem Description |
Workaround or Resolution |
| PDD06D-961 |
On 7.10.1.80, after changing the hostname of the system, the host cert gets generated successfully.
However, the GUI does not restart and uses the old certificates. |
You can trigger a restart of the GUI by running "adminaccess enable https" CLI from DDSH.
This ensures that the new host certificate is used for GUI. |
7.10.1.70 Release (July 2025)
Associated Build Versions
- DDOS Build: 7.10.1.70-1181207
- DDVE Build: 7.10.1.70-1181207
- DDMC Build: 7.10.1.70-1181207
- BoostFS Build: 7.10.1.70-1178590
DDOS File System
| Fixed Issue |
Description |
| DDOSCFD-21785 |
Resolved an issue where there was a filesystem panic and restart. |
| DDOSCFD-24404 |
Fixed an issue where the total number of used streams is over the DD total streams. |
| DDOSCFD-25498 |
Fixed an issue where RAID PANIC occurred due to total failure of HU DG. |
DDOS Platform
| Fixed Issue |
Description |
- DDOSCFD-26394
- PDD09I-298
- PDD09I-302
|
Fixed multiple issues where there were kernel panics due to memory leaks. |
DDOS Network
| Fixed Issue |
Description |
| DDOSCFD-24480 |
Resolved an issue wherein the user could not disable DD Boost using REST API limited-admin user token. |
DDOS Security
| Fixed Issue |
Description |
| DDOSCFD-24769 |
Fixed an issue where there was a constant PAM error after upgrade. |
| DDOSCFD-25454 |
Fixed an issue where there was a DDOS upgrade failure from 8.1.0.011 to 8.3.0.15 due to missing /ddvar/certificates. |
DDMC
Unsupported Feature
| Feature |
Description |
| Smart Scale |
The Smart Scale feature is not supported in this release. To access this feature, upgrade to the latest LTS release.
NOTE: The Smart Scale feature will be deprecated in future 7.10 LTS releases. |
7.10.1.60 Release (April 2025)
Associated Build Versions
- DDOS Build: 7.10.1.60-1161253
- DDVE Build: 7.10.1.60-1161253
- DDMC Build: 7.10.1.60-1161253
- DD BoostFS Build: 7.10.1.60-1158086
Changed features
| Issue |
Description |
Workaround or Resolution |
| DDOS-289508 |
NFS export /ddvar is replaced with five new exports: /ddvar/core, /ddvar/log, /ddvar/traces, /ddvar/releases, and /ddvar/support
The exports created before the upgrade do not retain the previously added client information. The clients who have mounted /ddvar/ on these directories encounter a Stale File Handle.
|
The client information for these exports must be added again after the upgrade. These clients must unmount and then remount the new exports. |
| DDOS-289508 |
If a share is created with /ddvar/<x>, it changes to /ddvar during the upgrade. With the new changes, mounting subdirectories of /ddvar does not work with CIFS. |
Use the /ddvar share to access its sub folders. |
DDOS General
| Fixed Issue |
Description |
| DDOSCFD-23619 |
Resolved an issue that prevented the use of '@' char in the user interface username field for Test Connectivity. |
DDOS Networking
| Fixed Issue |
Description |
| DDOS-287165 |
Resolved an issue by implementing a rule to drop ICMP time requests on DDMC. |
DDOS Platform
| Fixed Issue |
Description |
| DDOSCFD-23307 |
Fixed an issue where the TPM status was displayed as TPM device was not available after the upgrade to 7.10.1.40. |
| DDOSCFD-22652 |
Fixed a code issue that was restricting DD to send the disk failure alerts to CloudiQ. |
| DDOS-289678 |
Updated rc.sysinit to clean bash and profile scripts in /ddr/var tree during DDOS fresh install and upgrade. |
DDOS Security
| Fixed Issue |
Description |
| DDOS-289906 |
Fixed an issue where the files under /ddr/var/core or /ddvar/core path were not listed on the FTP share. |
DDOS Storage
| Fixed Issue |
Description |
| DDOSCFD-21154 |
Resolved an issue by modifying the behavior of the pending disk status to reflect a failed disk for the OS disk. |
7.10.1.50 Release (January 2025)
Associated Build Versions
- DDOS Build: 7.10.1.50-1146826
- DDVE Build: 7.10.1.50-1146826
- DDMC Build: 7.10.1.50-1146826
New Feature
| Functional Area |
Feature Description |
Summary of Benefit |
| Security |
Added support for TLS 1.3 and ECDHE ciphers when communicating with an external KMIP server. |
When DDOS communicates with an external KMIP server, it can use the TLS 1.3 protocol if the KMIP server supports it. This enhances security during communication with the external KMIP server. |
DDOS File System
| Fixed Issue |
Description |
| DDOSCFD-21087 |
Fixed an issue where the file system restart with no panic string after the system upgrade. |
| DDOSCFD-20874 |
Fixed the migration issue and updated metadata for a cloud unit that was inactive from long time. |
| DDOSCFD-20198 |
Fixed an issue that was created PANIC in the Cyber Recovery Environment. |
DDOS General
| Fixed Issue |
Description |
| DDOSCFD-21578 |
Fixed an issue where DDBOOST client information was spamming Autosupport files, leading to the truncation of important data on Elysium. |
| DDOSCFD-21289 |
Resolved the issue in the Update tab, where the new registry entries were added in addition to existing AD entries creating inconsistencies. |
| DDOSCFD-20984 |
Fixed an issue where the cmc_dump -L command did not allow specifying an optional directory path with sufficient space for container dumps. |
| DDOS-272707 |
Fixed an issue where page numbers were removed in the downloaded Tenant Replication Overview PDF report. |
DDOS Platform
| Fixed Issue |
Description |
| DDOSCFD-22529 |
Fixed an issue where an error was observed while performing an upgrade precheck. |
| DDOSCFD-22462 |
Fixed an issue where users were unable to create an iDRAC user while enabling the Remote Lifecycle Controller (RLC). |
| DDOS-271782 |
Fixed an issue where iSM was running in Limited Functionality Mode during the initrd phase on KOS. |
DDOS Security
| Fixed Issue |
Description |
| DDOSCFD-22818 |
Fixed an issue that was encountered when adding a new Data Domain to Avamar. |
| DDOSCFD-22813 |
Fixed an issue where the DDOS was displaying an incorrect valid until date for the Root Certificates. |
| DDOSCFD-22660 |
Resolved an issue causing the HA upgrade to fail on the Active Node due to a firmware upgrade error. |
| DDOSCFD-21535 |
Fixed an issue where, after a DDOS upgrade, DD entered a limited session state, and the user interface was not accessible, followed by an "incorrect username or password" error. However, logging in through Putty or CLI with the same sysadmin credentials was successful. |
| DDOSCFD-21459 |
Resolved the multifactor authentication issue that caused the file system to crash while running a few commands. |
| DDOS-268198 |
Fixed an issue where the Reset Password prompts did not accept case-insensitive options. |
Associated Build Versions
- DDOS Build: 7.10.1.40-1126469
- DDVE Build: 7.10.1.40-1126469
- DDMC Build: 7.10.1.40-1126469
New Features
| Functional Area |
Feature Description |
Summary of Benefit |
| Security |
Support to reset sysadmin and security officer password from DDSH on DDR using password recovery token. |
Support is available to reset sysadmin and security-officer passwords on DDR. Use the newly available CLIs to configure DDR to reset password over SSH and Serial-port. |
| Support |
This feature provides on-demand DD Hardware Health Check, which can be run through CLI command "support healthcheck hardware." It collects information about the DD Hardware, analyses the collected information to identify issues and anomalies, and it recommends the next steps if there is any issue identified. |
This feature provides comprehensive and user-friendly DD hardware diagnostic experience to without involving support. |
DDOS File System
| Fixed Issue |
Description |
| DDOSCFD-20841 |
Resolved the Active Directory issue that was preventing non-admin users from accessing certain features. |
| DDOSCFD-20347 |
Implemented retry functionality for CIFS restart on the standby node to ensure that the HA standby node maintains connectivity to AD. |
| DDOSCFD-18403 |
Fixed the issue for the customer-imported certificates in DDSM Smart Scale, where the externally signed certificates are stored in the HTTPS certificate root folder. |
| DDOSCFD-17464 |
Resolved a problem with the data backup and replication schedule within the mtree. |
| DDOSCFD-15854 |
Resolved a problem causing the DDFS to restart unexpectedly because of an unstable file system. |
DDOS General
| Fixed Issue |
Description |
| DDOSCFD-20929 |
Modified the log extraction logic fix the slow return of the log view CLI. |
| DDOSCFD-20740 |
Resolved the truncation issue in the DD REST API response for hostnames exceeding 49 characters. |
| DDOSCFD-17190 |
Introduced a feature in cmck to verify and restore the value of cms_type following corruption. |
| DDOSCFD-16738/15190 |
Fixed the issue where the cache object remained unlocked during an iget operation for an element associated with that object. |
| DDOS-204028 |
Fixed an issue where the user could not run CLI to view recovery email address set for sysadmin and security officer user accounts. |
| DDOS-204023 |
Fixed an issue where the user could not update and show the email address used for resetting forgotten passwords using REST APIs. |
| DDOS-204014 |
Fixed an issue where the user would not get any prompt during the day 1 CLI setup process to update email address for resetting the password. |
DDOS Platform
| Fixed Issue |
Description |
| DDOSCFD-20565 |
Fixed the issue where DDMC reports were showing inaccurate utilization figures for certain managed systems. |
| DDOSCFD-20541 |
Resolved the problem causing the DD system to reboot with a Kernel Panic message following the disk replacement. |
| DDOSCFD-18795 |
Resolved the booting issue following the upgrade to DDOS 7.7.5.25. |
| DDOS-255280 |
Fixed an issue involving memory duplication created during the delayed deletion. |
DDOS Replication
| Fixed Issue |
Description |
| DDOSCFD-20260 |
Fixed the syncing issue with reverse replication from the Cyber Recovery vault back to the Production system. |
DDOS Security
| Fixed Issue |
Description |
| DDOSCFD-19860 |
Issue fixed for the system logging into security user instead of admin user after the headswap from DD6800 to DD9400. |
| DDOSCFD-18451 |
Introduction of new privileges for secure access. |
| DDOS-241314 |
Implemented customized PAM that prompts the customer to reset the password when the customer tries to log in three times with an incorrect password. |
| DDOS-255654 |
Fixed an issue where the customer was unable to reset the forgot password for sysadmin/SO user. |
Associated Build Versions
- DDOS Build: 7.10.1.30-1105324
- DDVE Build: 7.10.1.30-1105324
- DDMC Build: 7.10.1.30-1105324
DDOS File System
| Fixed Issue |
Description |
| DDOSCFD-19783 |
Fixed the issue where users were unable to log in to Enterprise Manager (EM) after configuring LDAP. |
| DDOSCFD-19311 |
This fix addresses the HSTS missing from HTTPS server. |
| DDOSCFD-18403 |
Fixed the issue for the customer-imported certificates in DDSM Smart Scale, where the externally signed certificates are stored in the HTTPS certificate root folder. |
| DDOSCFD-18267 |
Fixed the issue of PANIC due to race condition in AIR REPL workflow causing the PANIC in customer environment. |
| DDOS-229120 |
Fixed the issue of service denial when the export file overwrites the .system file. |
| DDOS-207653 |
Fixed the issue of Autosupport command that does not display an error for the invalid command. |
| DDOS-181245 |
Fixed the issue of Network Time Protocol (NTP) backporting done and vulnerabilities. |
DDOS General
| Fixed Issue |
Description |
| DDOSCFD-19046 |
Fixed the issue of static routes missing after upgrading to DDOS 7.10.1.15. |
| DDOSCFD-18428 |
Fixed the issue where DD UI does not display the VTL tapes from Cloud Tier. |
DDOS Platform
| Fixed Issue |
Description |
| DDOSCFD-19507 |
Fixed the issue that restarts the system from panic due to online OEC platform. |
| DDOSCFD-19467 |
Fixed the issue of active/cache/cloud tier unavailable alert appearing after headswap failure. |
| DDOSCFD-18760 |
This fixes the issue of file system panic observed when you run the dd_sptool --resync command. |
| DDOSCFD-17954 |
Fixed the issue of display error: "This command has unexpectedly aborted." |
| DDOS-234450 |
Fixed the issue of the Async procedure taking longer and displays a message: "PANIC: ddr/nfs/nfs_rpc.c: nfs_rpc_debug_cb: 427". |
| DDOS-173347 |
Fixed the issue of storage expansion failure. |
DDOS Replication
| Fixed Issue |
Description |
| DDOSCFD-18348 |
Fixed the issue to handle fanout error when running the replication. |
DDOS Security
| Fixed Issue |
Description |
| DDOS-216358 |
Fixed the issue to remove unvalidated redirects and forwards when DDSM accepts untrusted inputs. |
| DDOS-177759 |
Fixed the issue on Smart Scale DDOS 7.10 of running DDMC application with root privileges by default. |
Associated Build Versions
- DDOS Build: 7.10.1.20-1090468
- DDVE Build: 7.10.1.20-1090468
- DDMC Build: 7.10.1.20-1090468
- OST Plugin Build: 7.10.1.20-1083082
DDOS Security
| Fixed Issue |
Description |
| DDOS-179017 |
Remediation of LDAP injection security vulnerability. |
| DDOS-197917 |
Remediation for CVE-2023-0464,CVE-2023-0466,CVE-2023-0465,CVE-2023-2650. |
| DDOS-205345 |
Remediation for NVD CVE-2022-1271 (BDSA-2022-0958). |
| DDOS-208574 |
Remediation of registry value vulnerability. |
| DDOS-213045 |
Remediation of "se view" command vulnerability. |
| DDOS-213050 |
Remediation of Smart Scale password vulnerability. |
| DDOS-224614 |
A system passphrase force-update regression was required after the previous access mode was deprecated. |
| DDOSCFD-13936 |
Remove MD5 and 96-bit MAC algorithms in SSH. |
| DDOSCFD-16292 |
Remediation of AD/LDAP group name issues. |
| DDOSCFD-16989 |
Disable SNMP agent in IDRAC and keep SNMPV1 for inter-communication of IDRAC trap to DDOS. |
| DDOSCFD-17069 |
IDRAC security banner added to remind the user not to change configuration in IDRAC. |
DDOS DD CIFS/NFS
| Fixed Issue |
Description |
| DDOS-222533 |
SS container base was regenerated for backporting. |
| DDOSCFD-16857 |
The API request or response was working, while the response contained incorrect information for CIFS status. |
DDOS DDMC
| Fixed Issue |
Description |
| DDOSCFD-16896 |
Fixed an issue where when attempting to create a PCM (Physical Capacity Measurement) schedule, no MTrees are listed in the target selection. |
DDOS File System
| Fixed Issue |
Description |
| DDOS-153559 |
The file system panicked after an upgrade. |
| DDOS-166378 |
There were improvements to fm_dump_async() to reduce the likelihood of the inode cache getting hot. |
| DDOS-172568 |
The "enclosure show topology" previously panicked. |
| DDOS-173495 |
SMS disk to copy start-up file after adding to PEM in the storage pool. |
| DDOS-177710 |
The file system was disabled and shut down. |
| DDOS-199911 |
This fix selectively uses filesys for deleting files in superblocks. |
| DDOS-200575 |
After pulling a disk from ithaca-14 Volume vol1 was unavailable! and disks were in zero state. |
| DDOS-208699 |
After the HU disk panicked, new disks were swapped. |
| DDOS-216870 |
The level log filling messages were debugged. |
| DDOS-217884 |
The DIV was changed to support 1.92 TB boot disks. |
| DDOS-219095 |
The 10 GC and 3 Scavenge DUTI failing due to "cm_oec"tool. |
| DDOS-224477 |
The DD Boost client version was updated for DD system upgrade compatibility. |
DDOSCFD-13100
DDOSCFD-16548 |
The garbage collection issue was addressed. |
| DDOSCFD-14559 |
The directory manager panicked after a system upgrade due to a CC partition issue. |
| DDOSCFD-15317 |
The system restarted and displayed this message: "PANIC: ddr/dm/dmbt_iface.c: dmbt_intr_page_split: 14546: iipage->hdr.free_offset != iipage->hdr.entry_count. Namespace issue?" |
| DDOSCFD-16184 |
The system was irresponsive after an upgrade. |
| DDOSCFD-16240 |
After an upgrade, the system received the error message: "PANIC: ddr/dm/dm_check.c: _dm_fsck_intern: 1812: Fatal Error" |
| DDOSCFD-17809 |
After the DDOS upgrade completed, the user noticed that the file system was not stable and kept restarting and failing. |
DDOS General
| Fixed Issue |
Description |
| DDOS-218452 |
This fix addresses the Lot 9 DAE PSU fan fault. |
| DDOS-222479 |
Updated the docker base image for CPS, MPS, db, db_mgr, and lockbox services. |
DDOS DD Networking
| Fixed Issue |
Description |
| DDOS-171022 |
The driver and firmware were updated for Intel and Broadcom devices. |
| DDOS-173403 |
An installation panicked due to rsync rpm file. |
| DDOS-222730 |
The user experienced an issue as "veth1667" for the port which was dedicated to the replication. The port remained down after fail back. |
| DDOS-225218 |
The member interface in a failover bond did not display the correct link state after a link failover in the bond. |
| DDOSCFD-17770 |
An HA failure was launched due lost of connectivity at all levels. |
| DDOSCFD-17780 |
User experienced the alert containing- "NOTICE: MSG-DDSH-00017: (tty=<>, session=7741, cradmin: command "net config veth0 up" exited with code: 61" getting generated. |
| DDOSCFD-17476 |
After an upgrade, the user had an issue with the "veth1667" port which is dedicated to the replication and remained down after fail back. |
| DDOSCFD-17481 |
HA failure launched due lost of connectivity at all levels. |
| DDOSCFD-17917 |
The DLM alias come up after a system upgrade. |
DDOS DD Platform
| Fixed Issue |
Description |
| DDOS-200884 |
The iDRAC life cycle log message generated by iDRAC 6.x had a prefix. |
| DDOS-223476 |
The historical database upgrade panicked after the system was upgraded. |
| DDOSCFD-12822 |
The HA pair did not dial home: "standby node can only manage pnode events" |
| DDOSCFD-15845 |
The platmon command did not post a DIMM faulty alert when a MEM0001 event occurred. The corresponding alert was not sent if it happened before the latest reset. |
| DDOSCFD-16146 |
The grub update caused the system to panic in post installation. |
| DDOSCFD-16158 |
The power supply generated alerts. |
| DDOSCFD-16484 |
The HA degraded alert due to SMS panic during sms_system_package_show_installed command with the message: "realloc(): invalid next size" |
| DDOSCFD-17165 |
An HA system was unable to retrieve firmware information. |
DDOS Protocol
| Fixed Issue |
Description |
| DDOS-211593 |
This release fixes the length of the serial number in the VTL response of the SCSI INQUIRY command for IBM TS3500 changer. Previously, the serial number was shown truncated to 10 characters instead of showing all 12 characters. |
| DDOSCFD-18206 |
The system corrects the DD hostname truncation, but resulted in a memory allocation error. |
DDOS Replication
| Fixed Issue |
Description |
| DDOS-162260 |
A DD file system core was observed after an HA failover. |
| DDOS-166885 |
An HA system was unable to bring the file system online after a lab power outage. |
Associated Build Versions
- DDOS Build: 7.10.1.15-1078832
- DDVE Build: 7.10.1.15-1078832
- DDMC Build: 7.10.1.15-1078832
| Fixed Issue |
Description |
| DDOSCFD-16516 |
Remediation of escalation of privilege vulnerability. |
| DDOSCFD-17123 |
Remediation of OS command injection vulnerability. |
| DDOSCFD-17599 |
Remediation of OS command injection vulnerability. |
| DDOSCFD-17600 |
Remediation of DOM-based XSS vulnerability. |
| DDOSCFD-17601 |
Remediation of SQL injection vulnerability. |
| DDOSCFD-17174 |
Remediation of improper path traversal and OS command injection vulnerabilities. |
Associated Build Versions
- DDOS Build: 7.10.1.10-1068159
- DDVE Build: 7.10.1.10-1068159
- DDMC Build: 7.10.1.10-1068159
- DD BoostFS Build: 7.10.1.10-1058783
- OST Plugin Build: 7.10.1.10-1068159
DDOS Security
| Issue |
Description |
| DDOS-150916 |
Security fix to address vulnerabilities. |
| DDOS-155586 |
Security fix to address CVE-2022-0847. |
| DDOS-169498 |
Security fix to address vulnerabilities. |
| DDOS-194227 |
Security fix to address vulnerabilities. |
| DDOSCFD-14872 |
Security fix to address vulnerabilities. |
| DDOSCFD-14916 |
Security fix to address vulnerabilities. |
| DDOSCFD-14945 |
Security fix to address vulnerabilities. |
| DDOSCFD-15122 |
Security fix to address CVE-2022-31129. |
| DDOSCFD-15123 |
Security fix to address CVE-2021-23337. |
| DDOSCFD-15869 |
Security fix to address vulnerabilities. |
| DDOSCFD-15989 |
Security fix to address vulnerabilities. |
| DDOSCFD-16118 |
Security fix to address vulnerabilities. |
| DDOSCFD-16119 |
Security fix to address vulnerabilities. |
DDOS DD CIFS/NFS
| Issue |
Description |
| DDOS-180509 |
Inability to expire over CIFS to Compliance mode, caused the system to panic. |
| DDOSCFD-15631 |
This CIFS issue caused the system to panic. |
DDOS Cloud
| Issue |
Description |
| DDOS-189902 |
The filesys incorrectly reported a system panic. |
| DDOSCFD-15692 |
Incorrect panic was caused when HA mode was called by DDMC on a cloud system. |
| DDOSCFD-16463 |
The issue which caused the system to panic and the following message was fixed: "PANIC: ddr/repl/lrepl_client.c: filecopy_close_local: 12261: filecopy ctx 541: mismatched chksums orig -671012825 repl -1475858379" |
DDOS DD Boost
| Issue |
Description |
| DDOSCFD-16634 |
DD Boost OST issue caused the DD hostname to be truncated, causing the system to panic. |
DDOS File System
| Issue |
Description |
| DDOSCFD-14359 |
A system upgrade caused an LLC timeout which resulted in recovered inflight stripes. |
| DDOSCFD-14503 |
Although the file system showed an active alert, the issue appeared as resolved on Cloud IQ. |
| DDOSCFD-14558 |
The file system panicked with this message "PANIC: ddr/dm/dm_mrepl.c: _dm_mrepl_filter_delta_buffer: 5096: No entry matching cookie". |
| DDOSCFD-14858 |
A firmware upgrade caused the file system to become unavailable. |
| DDOSCFD-15256 |
After an upgrade was completed, the disks showed as "known status" and the file system showed as "not existing". |
| DDOSCFD-15336 |
The file system issue which caused this message was fixed. "PANIC: ddr/dm/dmbt_iface.c: dmbt_scm_cache_sync_lock_free: 5602: Fatal Error" |
| DDOSCFD-15649 |
The issue that caused the file system to panic and shutdown after an upgrade was fixed. |
| DDOSCFD-15650 |
This disk panic caused an HA node to become degraded. |
| DDOSCFD-15867 |
A system panic occurred when customer had huge capacity values. |
| DDOSCFD-15978 |
The file system restarted multiple times and caused the following error, aaaaaaaa'PANIC: ddr/dm/dmbt_iface.c: dmbt_get_entry_inode: 19746: !(ret == DD_ERR_NONEa' |
| DDOSCFD-16012 |
This file system issue caused the system to restart. |
| DDOSCFD-16121 |
A firmware update caused the file system to become unavailable. |
DDOS DD Platform
| Issue |
Description |
| DDOSCFD-14690 |
The fix addresses this issue that occurred after an upgrade. "WARNING Firmware EVT-FIRMWARE-00002: One or more of the system's hardware components is running on an outdated firmware version." |
| DDOSCFD-15119 |
The fix handles the exception when the PTAgent is not working during an upgrade. |
DDOS Replication
| Issue |
Description |
| DDOSCFD-15598 |
This DD Boost issue caused a system panic during replication: "PANIC: ddr/repl/srepl.c: srepl_do_process_pattern_match: 2090: !(*remote_array_offset < max_candidates)". |
| DDOSCFD-15879 |
A replication issue caused this system message, "PANIC: ddr/repl/lrepl_client.c: mrepl_send_file: 16638: repl ctx 6:1: mrepl_send_file: I/O error". |
Associated Build Versions
- DDOS Build: 7.10.1.1-1049892
- DDVE Build: 7.10.1.1-1049892
- DDMC Build: 7.10.1.1-1049892
DDOS Security
| Issue |
Description |
| DDOS-132808 |
Security fix to address vulnerabilities. |
| DDOS-158902 |
Security fix to address vulnerabilities. |
| DDOS-159075 |
Security fix to address vulnerabilities. |
| DDOS-164179 |
Security fix to address vulnerabilities. |
| DDOS-173793 |
Security fix to address vulnerabilities. |
| DDOS-175886 |
Security fix to address vulnerabilities. |
| DDOS-178008 |
Security fix to address vulnerabilities. |
| DDOS-193150 |
Security fix to address vulnerabilities. |
Associated Build Versions
- DDOS Build: 7.10.1.0-1042928
- DD BoostFS Build: 7.10.1.0-1041872
DDOS Security
| Issue |
Description |
| DDOS-173372 |
Upgraded Dell BSAFE Crypto-J for FIPS 140-2 compliance. |
| DDOS-177737 |
Upgraded Dell BSAFE Crypto-J for FIPS 140-2 compliance |
| DDOS-182101 |
The fix addressed the iDRAC9 vulnerability. |
| DDOSCFD-13969 |
Removed SCP command in DDSH. |
DDOS Cloud
| Issue |
Description |
| DDOSCFD-14068, DDOSCFD-14194 |
Users were unable to delete files while files are open in the app. The system now allows the expired WORM files to be renamed. |
| DDOSCFD-12626, DDOSCFD-14629 |
The system experienced alerts: "EVT-ENVIRONMENT-00040: Unsupported virtual hardware configuration. The root cause is that the disk order is changed after rebooting DDVE in Azure. |
| DDOSCFD-13035 |
File distribution or tier was missing from ASUP. |
| DDOSCFD-13520 |
Users were unable to delete files while files are open in the app. The system now allows the expired WORM files to be renamed. |
DDOS DD Boost
| Issue |
Description |
| DDOS-168633, MDT-473769 |
DD backups panic in a high latency environment. The race condition was fixed by adding a lock for refcount operations. |
| DDOSCFD-14068, DDOSCFD-14194 |
DDFS panic was seen when applications using DD Boost ingest data with file paths that contained spaces. The logic was fixed to extract the correct "su" name from a file path that contained spaces. The buffer length was also fixed to only have enough space to accommodate the maximum storage-unit name. A DDOS upgrade is required for the fix. |
DDOS File System
| Issue |
Description |
| DDOSCFD-13580 |
When the check for read-only files was added, this file manager issue caused the error: “Hmon: PANIC: abort due to timeout in "DDFS CRON" - stream_upgrade_lock waiting on condition lock”. |
| DDOS-169149, DDOS-169333 |
The input string was not validated properly if the string was "Fixed-8K" for the filesys option set anchoring-algorithm CLI command. |
| DDOSCFD-12265 |
Directory manager issue caused inconsistent "last verified file timestamp" values. |
| DDOSCFD-12859 |
The client call did not reach the SMS server, and the client code did not honor the error received. |
| DDOSCFD-12993 |
The system experienced a passphrase authorization issue. |
| DDOSCFD-14188, DDOSCFD-14297, DDOSCFD-14465 |
A file manager issue caused a system panic with an error message: PANIC: ddr/fm/fm_server.c: fms_iterator_compare_and_update: 6034: Fatal Error |
DDOS General
| Issue |
Description |
| DDOSCFD-13078 |
When changing user roles, "DD Boost is not licensed" is displayed and cannot be changed. |
| DDOSCFD-13147 |
For DD systems where only legacy licenses are present, a warning in global alerts shows that "No licenses are present on this system. A license must be added for continued usage of the system." |
| DDOSCFD-13578 |
On the DD user interface, "filesys expand" command shows the incorrect current active tier size. |
DDOSCFD-13843,
DDOSCFD-15357 |
The left side of the menu is unclickable after checking the file system page for HA systems. |
| DDOSCFD-14337 |
The config payload field haEnabled value returned null for the system. |
DDOS DD Networking
| Issue |
Description |
| DDOSCFD-13878 |
A DD system experienced the wrong time zone conversion for Africa: Casablanca region. |
| DDOSCFD-14096 |
Network interfaces on DD3300 become unusable with "no autoneg" status. |
| DDOSCFD-14098 |
Backup jobs ran slowly and issued many warnings when the NIC switch panicked. |
DDOS DD NFS/CIFS
| Issue |
Description |
| DDDOSCFD-13520, HAT-418 |
Permission was denied on an enabled Mtree when the ARL code checked for the Mtime time_sec attribute. |
DDOS DD Platform
| Issue |
Description |
| DDOS-170365 |
The ASUP code did not include DD6400 as a supported platform when generating a value for DELL_SERVICETAG. |
| DDOS-156224 |
The LOT9 PSU YJ95T is compatible with DD6400, DD6900, DD9400, and DD9900 since the release of version 7.10. |
| DDOSCFD-11926 |
A DD system on a DD9900 experienced erroneous disk failure after DIMM replacement. |
| DDOSCFD-12332 |
An alert was recorded when the power cable was unplugged, but is cleared immediately. The alert was also detected and cleared when the cable was plugged in. |
| DDOSCFD-12982 |
A buffer copy issue caused the operating system drive to panic. |
| DDOSCFD-13380, DDOSCFD-13573 |
Reconstruction could not start after a disk replacement on a DD9900 system. |
| DDOSCFD-13493 |
System failed precheck during upgrade. |
| DDOSCFD-13939 |
After upgrading HA system from 7.7.3 to 7.7.4, the standby node upgrade status is "in progress", but active node upgrade status is "Succeeded." |
| DDOSCFD-14304 |
The disk cache policy issue for DD3300 capacity expansion was disabled. |
DDOS Replication
| Issue |
Description |
| DDOSCFD-13194, DDOSCFD-13826, DDOSCFD-285 |
File system panic occurred with payload chunk exceeded the maximum limit. Error message included: PANIC: ddr/dm/dm_attr_iface.c: dm_attr_set: 151: !(chunk_id < DM_ATTR_CHUNK_ID_ALL). |