Avamar ADS Gen5:事件代碼 = 52804 發生記憶體裝置錯誤

Summary: 事件代碼 = 52804,發生記憶體裝置錯誤

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

在 MCCLI 事件顯示、Avamar 使用者介面 (AUI) 事件頁面,或 /var/log/messages 中,可能會顯示類似此訊息:

EventID: 52804 A memory device error occurred. The system may continue to function as normal (except for a multibit error). Replace the memory module identified in the message during the system's next scheduled maintenance. Clear the memory error on multibit ECC error. The memory device status and location are provided

Cause

預測性 DIMM 故障

Resolution

登入受影響的節點並執行下列命令:

Omreport chassis memory

可能會傳回類似以下內容的故障記憶體插槽:

Index          : 3
Status         : Critical
Connector Name : A4
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB

一般記憶體插槽的輸出範例:

Index          : 6
Status         : Ok
Connector Name : B1
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB

未佔用的記憶體插槽仍有連接器名稱。未佔用記憶體插槽的輸出範例:

Index          :
Status         : Unknown
Connector Name : A7
Type           : [Not Occupied]
Size           :

有幾個錯誤代碼組成了這個症狀代碼。其中大多數不需要採取任何行動。下列事件代碼需要採取行動。

請注意,錯誤代碼可能會指定為事件代碼、MessageID 或代碼:

 
錯誤代碼 說明 建議的動作
MEM0001 在位於 arg1 的記憶體裝置上偵測到多位記憶體錯誤。 請立即更換 DIMM。
MEM0702 系統偵測到並修正記憶體錯誤 重新開機系統,以啟用可能的記憶體自我修復功能。
MEM9072 系統記憶體在位於 arg1 的記憶體裝置非執行路徑中,有無法修正的多位元記憶體錯誤。 請立即更換 DIMM
MEM0702 
「已超過 DIMM_XX 的可修正記憶體錯誤率。」
請立即更換 DIMM

如果上述建議的動作是更換 DIMM,請使用「連接器名稱」以指定應更換的插槽。不需要像 Gen4t 那樣更換多個插槽。

Affected Products

Avamar Data Store Gen5A
Article Properties
Article Number: 000214852
Article Type: Solution
Last Modified: 30 Jun 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.