Connectrix: B-Series MS-1009 Events Reported on Switch Port

Summary: MS-1009 events are reported on the switch Port.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Index Slot Port Address Media  Speed        State    Proto
============================================================
306    8   18   01xxx0   id    32G   No_Light    FC 
 
CURRENT CONTEXT -- 0, 128
/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
306:  195.1m   68.4m    0       0       0       0       0       0       0       0       6.7k    0       1.3k   13       0       0       0       0      37.2m

 
=============
Slot  8/Port 18:
=============
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist

RX Power:    -inf    dBm (0.0  uW)
TX Power:    0.2     dBm (1053.1 uW)

 
2023/11/20-18:20:34 (IST), [MS-1009], 287, SLOT 1 | FID 128 | PORT 8/18, ERROR, SAN, RLIR event. Slot/Port 8/18 (01xxx0). Device Port Tag is 0x0100. Not Operational Sequence Recognized.

2023/11/20-18:20:49 (IST), [MS-1009], 288, SLOT 1 | FID 128 | PORT 8/18, ERROR, SAN, RLIR event. Slot/Port 8/18 (01xxx0). Device Port Tag is 0x0100. Not Operational Sequence Recognized.

2023/11/20-18:40:06 (IST), [MS-1009], 291, SLOT 1 | FID 128 | PORT 8/18, ERROR, SAN, RLIR event. Slot/Port 8/18 (01xxx0). Device Port Tag is 0x0100. Not Operational Sequence Recognized.

2023/11/20-19:10:56 (IST), [MS-1009], 298, SLOT 1 | FID 128 | PORT 8/18, ERROR, SAN, RLIR event. Slot/Port 8/18 (01xxx0). Device Port Tag is 0x0100. Not Operational Sequence Recognized.

2023/11/20-19:57:47 (IST), [ZONE-1007], 304, SLOT 1 | FID 128 | PORT 8/18, INFO, SAN, Ioctl (UAM Zoning Enforcement) in (unhandled error occured) at port (306) returns code (-95) and reason string (ZONING_TYPE_NOT_SET).

2023/11/20-20:00:13 (IST), [MS-1009], 305, SLOT 1 | FID 128 | PORT 8/18, ERROR, SAN, RLIR event. Slot/Port 8/18 (01xxx0). Device Port Tag is 0x0100. Not Operational Sequence Recognized.

Cause

This message Indicates a registered link incident record (RLIR) is generated for one of the actions indicated by the message value.

The message value can be one of the following:
  • Exceeded bit error-rate threshold
  • Loss of signal or synchronization
  • Not operational sequence recognized  
  • Primitive sequence timeout
  • Unrecognized link incident

Resolution

Persistent RLIR incidents are likely the result of SAN hardware issues such as bad cables or small form-factor pluggable (SFP) transceivers. If the message persists, replace the fiber-optic connector (FC) Cable.

Additional Information

For more details, see the Brocade article Message Reference GuideThis hyperlink is taking you to a website outside of Dell Technologies.