Connectrix: Brocade: Management Port is flapping

Summary: Ping results to FC switch show 100% and 0% in short duration. This KB explains what causes the issue and how to fix it.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The issue was noticed when the IP switch port was blinking amber and the ping to the switch was not working intermittently. 

If you have physical access to the switch, follow the below KB article and see if the issue gets fixed:
https://www.dell.com/support/kbdoc/en-in/000059228/connectrix-b-series-brocade-how-to-recover-from-hung-state-on-management-ethernet-port-with-no-access-using-webtools-telnet-or-ssh

Cause

This is a rare hardware issue. 

Resolution

Resolution:
1) Replace the Management Cable between FC and IP switch. 
2) Reboot the switch during the downtime as it is disruptive. 
3) If the issue is not resolved, replace the Switch.  

Affected Products

Connectrix B-Series
Article Properties
Article Number: 000224089
Article Type: Solution
Last Modified: 16 Apr 2024
Version:  1