PowerEdge:Dell Enterprise Intel 固態硬碟可能會回報故障或故障狀況
Summary: Dell Intel SATA 固態硬碟可能會回報無法正常運作的 PDR3 事件,可能會導致磁碟機故障的狀況。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
遇到或觀察到下列症狀:
- 磁碟機故障
- 遺失磁碟機
- iDRAC 未偵測到磁碟機
在某些情況下,此故障還可能觸發背板電壓錯誤。
範例記錄:
Lifecycle Controller (LC) 記錄範例:
11/2/2023 8:32 iDRAC Storage Critical PDR3 The Physical Drive (PD) Disk 0 in Backplane 1 of Integrated RAID Controller 1 is not correctly functioning. Part number TW00xxxxxxxxxxxxxxxA00. 11/9/2023 5:11 iDRAC Storage Critical PDR3 The Physical Drive (PD) Disk 3 in Backplane 1 of Integrated RAID Controller 1 is not correctly functioning. Part number TW00xxxxxxxxxxxxxxxA00. 11/9/2023 5:11 SEL System Health Critical VLT0204 The system board BP1 PG voltage is outside of range. 11/17/2023 0:53 SEL System Health Critical VLT0204 The system board Pfault fail-safe voltage is outside of range. 11/17/2023 0:53 SEL System Health Critical VLT0204 The system board BP1 PG voltage is outside of range.
PERC TTY 記錄範例:(PHY 不良事件):
C0:EVT#60333-06/11/24 14:55:20: 185=Enclosure PD 40(c None/p1) phy bad for slot 1 C0:ld sync: all LDs sync'd, 00 offline lds, of 01 total lds C0:EVT#02534-12/07/23 0:37:50: 185=Enclosure PD 40(c None/p1) phy bad for slot 3 C0:SMBE: Ses Bad Phy RC 4 ePd 40 s 3 be 3
Cause
Dell Technologies 已發現可能導致 Dell Intel 固態硬碟發生非預期故障的韌體問題。
在 DL7A 新版本之前的任何韌體版本上運作的這些磁碟機,都可能發生過早故障。
受影響的 Intel 磁碟機零件編號:
DPN Description Firmware w/ Fix 00DJ5 SSDR,480G,2E,IT06,2.5,I-YV,EC DL7A 5M8Y4 SSDR,960G,RET2,2.5,YOUNGSVI,EC DL7A D5C1D SSDR,480G,MET2,2.5,YOUNGSVI,EC DL7A 6J65H SSDR,1.9T,RET2,2.5,YOUNGSVI,EC DL7A 6XW3M SSDR,1.9T,MET2,2.5,YOUNGSVI,EC DL7A KM4C4 SSDR,3.8T,RET2,2.5,YOUNGSVI,EC DL7A 53KHR SSDR,480G,RET2,2.5,YOUNGSVI,EC DL7A DYMD0 SSDR,960G,MET2,2.5,YOUNGSVI,EC DL7A 572Y6 SSDR,3.8T,MET2,2.5,YOUNGSVI,EC DL7A
GHD66 SSDR,240G,RET2,2.5,YOUNGSVI,EC DL7A
XKP9T SSDR,7.6T,RET2,2.5,YOUNGSVI,EC DL7A 7KDJJ SSDR,3.8T,2E,IT06,2.5,I-YV,EC DL7A 8MHYH SSDR,960G,2E,IT06,2.5,I-YV,EC DL7A 8RXV5 SSDR,1.9T,2E,IT06,2.5,I-YV,EC DL7A F6H8H SSDR,960G,2E,IT06,2.5,I-YV,EC DL7A GX439 SSDR,480G,2E,IT06,2.5,I-YV,EC DL7A VYYW8 SSDR,1.9T,2E,IT06,2.5,I-YV,EC DL7A WNPN1 SSDR,3.8T,2E,IT06,2.5,I-YV,EC DL7A
CM88M SSDR,240G,2E,IT06,M.2,I-YV,EC DL7A
M7F5D SSDR,480G,2E,IT06,M.2,I-YV,EC DL7A
Resolution
將磁碟機韌體版本更新至 DL7A 或更新版本。
https://www.dell.com/support/home/drivers/driversdetails?driverid=9rf8x
此更新已歸類為緊急,應儘早應用。
Dell Technologies 強烈建議您儘快套用此重要更新。此更新包含的重大錯誤修正和變更,可改善 Dell 系統功能、可靠性及穩定性。其也可能包含安全性修正和其他增強功能。
Affected Products
PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX840C, PowerEdge R240, PowerEdge R250, PowerEdge R340, PowerEdge R350
, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R840, PowerEdge R940, PowerEdge R940xa, PowerEdge T140, PowerEdge T150, PowerEdge T340, PowerEdge T350, PowerEdge T440, PowerEdge T550, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7420, PowerEdge XE7440, PowerEdge XE8545, PowerEdge XR11, PowerEdge XR12
...
Products
PowerFlex appliance R650, PowerFlex appliance R6525, Powerflex appliance R750, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840Article Properties
Article Number: 000226989
Article Type: Solution
Last Modified: 04 Sep 2025
Version: 12
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.