PowerEdge:Dell Enterprise Intel SSD 驱动器可能会报告故障或故障情况
Summary: 戴尔英特尔 SATA SSD 驱动器可能会报告无法正常工作的 PDR3 事件,这可能会导致驱动器故障情况。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
遇到或观察到以下症状:
- 发生故障的驱动器
- 缺少驱动器
- iDRAC 未检测到驱动器
在某些情况下,此故障还可能触发背板电压错误。
日志示例:
Lifecycle Controller (LC) 日志示例:
11/2/2023 8:32 iDRAC Storage Critical PDR3 The Physical Drive (PD) Disk 0 in Backplane 1 of Integrated RAID Controller 1 is not correctly functioning. Part number TW00xxxxxxxxxxxxxxxA00. 11/9/2023 5:11 iDRAC Storage Critical PDR3 The Physical Drive (PD) Disk 3 in Backplane 1 of Integrated RAID Controller 1 is not correctly functioning. Part number TW00xxxxxxxxxxxxxxxA00. 11/9/2023 5:11 SEL System Health Critical VLT0204 The system board BP1 PG voltage is outside of range. 11/17/2023 0:53 SEL System Health Critical VLT0204 The system board Pfault fail-safe voltage is outside of range. 11/17/2023 0:53 SEL System Health Critical VLT0204 The system board BP1 PG voltage is outside of range.
PERC TTY 日志示例:(PHY BAD 事件):
C0:EVT#60333-06/11/24 14:55:20: 185=Enclosure PD 40(c None/p1) phy bad for slot 1 C0:ld sync: all LDs sync'd, 00 offline lds, of 01 total lds C0:EVT#02534-12/07/23 0:37:50: 185=Enclosure PD 40(c None/p1) phy bad for slot 3 C0:SMBE: Ses Bad Phy RC 4 ePd 40 s 3 be 3
Cause
Dell Technologies 已确定可能导致戴尔英特尔 SSD 驱动器出现意外故障的固件问题。
在新的 DL7A 版本之前的任何固件版本上运行的任何这些驱动器中的任何一个都可能会出现过早故障。
受影响的英特尔驱动器部件号:
DPN Description Firmware w/ Fix 00DJ5 SSDR,480G,2E,IT06,2.5,I-YV,EC DL7A 5M8Y4 SSDR,960G,RET2,2.5,YOUNGSVI,EC DL7A D5C1D SSDR,480G,MET2,2.5,YOUNGSVI,EC DL7A 6J65H SSDR,1.9T,RET2,2.5,YOUNGSVI,EC DL7A 6XW3M SSDR,1.9T,MET2,2.5,YOUNGSVI,EC DL7A KM4C4 SSDR,3.8T,RET2,2.5,YOUNGSVI,EC DL7A 53KHR SSDR,480G,RET2,2.5,YOUNGSVI,EC DL7A DYMD0 SSDR,960G,MET2,2.5,YOUNGSVI,EC DL7A 572Y6 SSDR,3.8T,MET2,2.5,YOUNGSVI,EC DL7A
GHD66 SSDR,240G,RET2,2.5,YOUNGSVI,EC DL7A
XKP9T SSDR,7.6T,RET2,2.5,YOUNGSVI,EC DL7A 7KDJJ SSDR,3.8T,2E,IT06,2.5,I-YV,EC DL7A 8MHYH SSDR,960G,2E,IT06,2.5,I-YV,EC DL7A 8RXV5 SSDR,1.9T,2E,IT06,2.5,I-YV,EC DL7A F6H8H SSDR,960G,2E,IT06,2.5,I-YV,EC DL7A GX439 SSDR,480G,2E,IT06,2.5,I-YV,EC DL7A VYYW8 SSDR,1.9T,2E,IT06,2.5,I-YV,EC DL7A WNPN1 SSDR,3.8T,2E,IT06,2.5,I-YV,EC DL7A
CM88M SSDR,240G,2E,IT06,M.2,I-YV,EC DL7A
M7F5D SSDR,480G,2E,IT06,M.2,I-YV,EC DL7A
Resolution
将驱动器固件版本更新到 DL7A 或更高版本。
https://www.dell.com/support/home/drivers/driversdetails?driverid=9rf8x
此更新已被归类为紧急,应尽早应用。
Dell Technologies 强烈推荐尽快应用此更新。此更新包含重要的错误修复和更改,以提高戴尔系统的功能、可靠性和稳定性。它还可能包括安全修复和其他功能增强。
Affected Products
PowerEdge C6420, PowerEdge C6520, PowerEdge C6525, PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX840C, PowerEdge R240, PowerEdge R250, PowerEdge R340, PowerEdge R350
, PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R840, PowerEdge R940, PowerEdge R940xa, PowerEdge T140, PowerEdge T150, PowerEdge T340, PowerEdge T350, PowerEdge T440, PowerEdge T550, PowerEdge T640, PowerEdge XE2420, PowerEdge XE7420, PowerEdge XE7440, PowerEdge XE8545, PowerEdge XR11, PowerEdge XR12
...
Products
PowerFlex appliance R650, PowerFlex appliance R6525, Powerflex appliance R750, PowerFlex appliance R640, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840Article Properties
Article Number: 000226989
Article Type: Solution
Last Modified: 04 Sep 2025
Version: 12
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.