O nó do PowerScale entra em pane com o erro: smsatReadLogExtCB: nenhum pccb correspondente encontrado

Summary: O nó do PowerScale entra em pane com o erro: smsatReadLogExtCB: no matching pccb found -- status 0x41 error 0x40 phy 5 lba 0x36ceff96 satNCQ 0x1 satOrgIOContext 0xfffffe8ef3da07a8 reqType 0x20001d00 sataTag 0x10 ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

O nó entra em pane com a pilha abaixo:

panic @ time 1728809334.451, thread 0xfffffe8ef3382b00: smsatReadLogExtCB: no matching pccb found -- status 0x41 error 0x40 phy 5 lba 0x36ceff96 satNCQ 0x1 satOrgIOContext 0xfffffe8ef3da07a8 reqType 0x20001d00 sataTag 0x10

time = 1728809334
cpuid = 2, TSC = 0x11360273d277825
Panic occurred in module pmspcv.ko loaded at 0xffffffff83de1000:

Stack: --------------------------------------------------
pmspcv.ko:smsatReadLogExtCB+0x66d
pmspcv.ko:smllSATACompleted+0xc9
pmspcv.ko:siIODone+0x152
pmspcv.ko:mpiSATACompletion+0x4c3
pmspcv.ko:mpiParseOBIomb+0x50e
pmspcv.ko:siProcessOBMsg+0xb9
pmspcv.ko:saDelayedInterruptHandler+0x1cd
pmspcv.ko:agtiapi_IntrHandlerx_+0x88
kernel:ithread_loop+0x21c
kernel:fork_exit+0x82
--------------------------------------------------
Disabling swatchdog
Dumping stacks (40960 bytes)

Cause

Um problema raro conhecido em que uma unidade SATA recebe solicitações pesadas de E/S causa essa pane.

Resolution

Solução temporária:
Defina o seguinte sysctl:

isi_sysctl_cluster hw.iosched.max_disk_inprog_limit=16

Solução permanente:
Faça upgrade para uma das seguintes versões ou posterior:
  • OneFS 9.4.0.16_GA-RUP_2023-11
  • OneFS 9.5.x

Affected Products

Isilon H500
Article Properties
Article Number: 000236632
Article Type: Solution
Last Modified: 23 Oct 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.