PowerScale 節點發生錯誤並顯示錯誤:smsatReadLogExtCB:找不到相符的 PCCB
Summary: PowerScale 節點發生錯誤並顯示錯誤:smsatReadLogExtCB:找不到相符的 PCCB -- status 0x41 error 0x40 phy 5 lba 0x36ceff96 satNCQ 0x1 satOrgIOContext 0xfffffe8ef3da07a8 reqType 0x20001d00 sataTag 0x10
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
節點發生以下堆疊錯誤:
panic @ time 1728809334.451, thread 0xfffffe8ef3382b00: smsatReadLogExtCB: no matching pccb found -- status 0x41 error 0x40 phy 5 lba 0x36ceff96 satNCQ 0x1 satOrgIOContext 0xfffffe8ef3da07a8 reqType 0x20001d00 sataTag 0x10 time = 1728809334 cpuid = 2, TSC = 0x11360273d277825 Panic occurred in module pmspcv.ko loaded at 0xffffffff83de1000: Stack: -------------------------------------------------- pmspcv.ko:smsatReadLogExtCB+0x66d pmspcv.ko:smllSATACompleted+0xc9 pmspcv.ko:siIODone+0x152 pmspcv.ko:mpiSATACompletion+0x4c3 pmspcv.ko:mpiParseOBIomb+0x50e pmspcv.ko:siProcessOBMsg+0xb9 pmspcv.ko:saDelayedInterruptHandler+0x1cd pmspcv.ko:agtiapi_IntrHandlerx_+0x88 kernel:ithread_loop+0x21c kernel:fork_exit+0x82 -------------------------------------------------- Disabling swatchdog Dumping stacks (40960 bytes)
Cause
SATA 磁碟機收到繁重的 I/O 要求會導致此死機的罕見已知問題。
Resolution
因應措施:
設定以下內容 sysctl:
isi_sysctl_cluster hw.iosched.max_disk_inprog_limit=16
永久解決方案:
升級至下列其中一個版本或更新版本:
- OneFS 9.4.0.16_GA-RUP_2023-11
- OneFS 9.5.x
Affected Products
Isilon H500Article Properties
Article Number: 000236632
Article Type: Solution
Last Modified: 23 Oct 2024
Version: 1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.