PowerStore: Node IPMI reported abnormal voltage levels.
Summary: PowerStore: Node IPMI voltage health state was changed. IPMI reported abnormal voltage levels.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
IPMI monitoring flags the voltage low on the coin cell (CMOS) battery in the node when it reaches a threshold below 2.20 volts. If the voltage level reaches a critical level, the node may reboot or fail.
ConnectHome event is generated for:
SymptomCode : 0x00303505 / 0x00303506
Component : BaseEnclosure-NodeX
Description: IPMI reported abnormal voltage levels.
Alert is active in UI for either of these conditions:
Alert ID XMS_NODE_VOLTAGE_HEALTH_LEVEL_5_MAJOR
Alert Text IPMI reported abnormal voltage levels.
Error Code 0x00303505
Description IPMI reported abnormal voltage levels.
Alert ID XMS_NODE_VOLTAGE_HEALTH_LEVEL_6_CRITICAL
Alert Text IPMI reported abnormal voltage levels.
Error Code 0x00303506
Description This indicates that the Node has failed due to a critical voltage reading.Cause
When the coin-cell battery in a node starts to fail, abnormal voltage reading alerts are active in the UI until the issue is resolved.
Resolution
Contact Dell Technical Support and reference this knowledge article for assistance.
Affected Products
PowerStoreArticle Properties
Article Number: 000248062
Article Type: Solution
Last Modified: 02 Jul 2026
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.