PowerFlex 4.x: Det går inte att distribuera PowerFlex-lagringskluster. Felet "Det gick inte att starta starten"

Summary: PowerFlex 4.x: Det går inte att distribuera PowerFlex-lagringskluster. Felet "Det gick inte att starta starten"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerFlex 4.x: Det går inte att distribuera PowerFlex-lagringskluster. Felet "Det gick inte att starta starten"

MDM-klustret har ännu inte bildats. Endast MDM-rpm är installerade på SVM-enheterna.

exception.log har följande fel:-

#<ASM::UserException: VXFM307::Bootstrap operation failed for operations: Bootstrap operation failed for operations: [{"name"=>".AddCaCommand",
      "message"=>"Command failed: Could not connect to XX.XX.XX.XX. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}, {"name"=>".AddCaCommand", "message"=>"Command failed: Could not connect to XX.XX.XX.YY. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}, {"name"=>".AddCaCommand", "message"=>"Command failed: Could not connect to XX.XX.XX.ZZ. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}].>

/opt/asm-deployer/lib/asm/provider/elementmanager/scaleio.rb:10156:in `configure_security_bootstrap'
/opt/asm-deployer/lib/asm/provider/elementmanager/scaleio.rb:10405:in `configure_scaleio_gateway'
/opt/asm-deployer/lib/asm/service_deployment.rb:4156:in `process_scaleio'

scaleio-block-legacy-gateway_exception.log har följande fel:-

#<ASM::UserException: VXFM307::Bootstrap operation failed for operations: Bootstrap operation failed for operations: [{"name"=>".AddCaCommand",
      "message"=>"Command failed: Could not connect to XX.XX.XX.XX. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}, {"name"=>".AddCaCommand", "message"=>"Command failed: Could not connect to XX.XX.XX.YY. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}, {"name"=>".AddCaCommand", "message"=>"Command failed: Could not connect to XX.XX.XX.ZZ. Ensure that the relevant service (LIA) is running and that the server can communicate with the node"}].>

LIA-spårningsloggar på SVM:erna fylls med följande med några sekunders mellanrum.

2024/12/13 15:34:12.925210 LOW:7ff568389db0:netPath_StartAsServer_CK:00539:  :: Disconnected Live SERVER path 0x7ff5683c8480 of portal (nil) net 0x8fb000 socket 14 inflights 0 HS:0 Start connection from IP XX.XX.XX.XX:43739 to XX.XX.XX.YY:9098
2024/12/13 15:34:12.925220 LOW:7ff568389db0:netPath_StartAsServer_CK:00552:  :: Disconnected Live SERVER path 0x7ff5683c8480 of portal (nil) net 0x8fb000 socket 14 inflights 0 HS:1 Registered with manager
2024/12/13 15:34:12.925735 LOW:7ff568389db0:netSec_Accept_CK:00310: Starting secure accept
2024/12/13 15:34:12.929886 MED:7ff568389db0:mosSecurity_PrintLibX509StoreCtxError:01115: SSL certificate verification error: unable to get local issuer certificate
2024/12/13 15:34:12.929900 LOW:7ff568389db0:mosSsl_HandleError:00429: ERROR: Handshake: error:1417C086:SSL routines:tls_process_client_certificate:certificate verify failed, SSL error: 1
2024/12/13 15:34:12.929903 LOW:7ff568389db0:netSec_SslHandshake_CK:00486: ERROR: Handshake failed (CERT_VERIFY_FAILURE)
2024/12/13 15:34:12.929905 LOW:7ff568389db0:netPath_StartAsServer_CK:00568: ERROR:  :: Disconnected Live SERVER path 0x7ff5683c8480 of portal (nil) net 0x8fb000 socket 14 inflights 0 HS:1 secure accept failure (CERT_VERIFY_FAILURE)

 

Följande kommando kördes på MVM med SVM:ernas IP-adresser för att validera att port 9099 för LIA var öppen

echo ""> /dev/tcp/XX.XX.XX.XX/9099 && echo "Port is open" || echo "not open"

Distributionen av PowerFlex Storage MDM Cluster misslyckades dock

Cause

Kunden hade en maskinvarubrandvägg som blockerade port 9099. 

Resolution

Kontrollera med kunden att de inte använder någon maskinvarubrandvägg som kan blockera LIA-kommunikation på port 9099 under distributionen.

Article Properties
Article Number: 000262080
Article Type: Solution
Last Modified: 23 Dec 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.