地理位置分散的灾难重启:使用动态 REXX API 发出 SRDF-HC 命令时,GDDR 无法识别非零返回代码
Yhteenveto: 使用动态 REXX API 发出主机组件命令时,GDDR 无法识别非零返回代码。
Tämä artikkeli koskee tuotetta
Tämä artikkeli ei koske tuotetta
Tämä artikkeli ei liity tiettyyn tuotteeseen.
Tässä artikkelissa ei yksilöidä kaikkia tuoteversioita.
Oireet
如果 SRDF 主机组件命令在 GDDR 脚本期间失败,消息GDDR313I可能会错误地指示 RC=0(如下例),脚本可以继续,就像命令成功一样。
GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
Syy
这是软件问题。
Tarkkuus
解决方案:
- 对于 GDDR 6.0,PTF GD60021解决了此问题。可从 Dell 在线支持下载。
- 对于 GDDR 5.3,PTF GD53104解决了此问题。可从 Dell 在线支持下载。
Lisätietoja
PTF 封面说明:
- GDDR 6.0L
++PTF(GD60021) REWORK(2023160) . ++VER(Z038) FMID(GDDR600) PRE( GD60014 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * * PROBLEM FIXED: GDDR-3601 * USERS AFFECTED: GDDR VMAX/PowerMax users * PROBLEM DESCRIPTION: GDDR script may not recognize non-zero * return code from SRDF HC command * * DESCRIPTION DETAIL: * * If an SRDF Host Component command fails during a GDDR * script, message GDDR313I could incorrectly indicate RC=0 * (example below) and the script could proceed as if the * command was successful. * * GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498 * * PROBLEM RESOLUTION: * * If an SRDF Host Component command fails during a GDDR * script, the return code will now be displayed correctly in * the GDDR313I message, and the script will handle the failure * as appropriate. * * In addition, message GDDR313I has been enhanced to avoid any * confusion as to what return code is displayed. Instead of * always indicating 'EMCSRDFR RC=', the message will now * indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=', * or 'IRXEXCOM RC=' so it is clear exactly which return code * is displayed. * * MODULES: GDDRDAP4 * GDDRMTXT * * ------------------------------------------------------------
- GDDR 5.3
++PTF(GD53104) REWORK(2023088) .
++VER(Z038) FMID(GDDR530)
PRE(
GD53096
)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3602
* USERS AFFECTED: GDDR VMAX/PowerMax users
* PROBLEM DESCRIPTION: GDDR script may not recognize non-zero
* return code from SRDF HC command
*
* DESCRIPTION DETAIL:
*
* If an SRDF Host Component command fails during a GDDR
* script, message GDDR313I could incorrectly indicate RC=0
* (example below) and the script could proceed as if the
* command was successful.
*
* GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
*
* PROBLEM RESOLUTION:
*
* If an SRDF Host Component command fails during a GDDR
* script, the return code will now be displayed correctly in
* the GDDR313I message, and the script will handle the failure
* as appropriate.
*
* In addition, message GDDR313I has been enhanced to avoid any
* confusion as to which return code is displayed. Instead of
* always indicating 'EMCSRDFR RC=', the message will now
* indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=',
* or 'IRXEXCOM RC=' so it is clear exactly which return code
* is displayed.
*
* MODULES: GDDRDAP4
* GDDRMTXT
*
* ------------------------------------------------------------
* GD53104 29 Mar 2023 14:49:11
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* GDDR-3602
*
*------------------------------------------------------------- Tuotteet, joihin vaikutus kohdistuu
Geographically Dispersed Disaster Restart (GDDR)Artikkelin ominaisuudet
Artikkelin numero: 000215551
Artikkelin tyyppi: Solution
Viimeksi muutettu: 29 heinäk. 2025
Versio: 3
Etsi vastauksia kysymyksiisi muilta Dell-käyttäjiltä
Tukipalvelut
Tarkista, kuuluuko laitteesi tukipalveluiden piiriin.