Il log dataheadsvc trasmette i seguenti errori:
Comando:# cat /opt/emc/caspian/fabric/agent/services/object/main/log/dataheadsvc.log
Esempio:
2018-08-16T10:13:35,312 [RpcDispatcherMD-1392] INFO COMMIT3Handler.java (line 132) Retrieved attributes for : 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240 Size : 1010564 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1441996478 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1458773694 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,317 [RpcDispatcherMD-1356-0a01821f:165323f0b49:ef:2838a52] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD 2018-08-16T10:13:35,318 [RpcDispatcherMD-1298-0a01821f:165323f0b49:e6:283489e] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD
Causa
La procedura NFS (Network File System) utilizzata dall'operazione client è LINK, ovvero il collegamento reale. Questa operazione non è supportata.
Risoluzione
NFS supporta tutte le procedure NFSv3 TRANNE LINK: Creare un collegamento reale a un oggetto.
Informazioni aggiuntive
Fare riferimento alla sezione NFS delle domande frequenti tecniche.
Prodotti interessati
Elastic Cloud StorageProdotti
Elastic Cloud StorageProprietà dell'articolo
Numero articolo: 000042857
Tipo di articolo: Solution
Ultima modifica: 12 set 2025
Versione: 4
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.