Dell Unity: Connection to UNITY via IPMI tool fails with "Error: Unable to establish IPMI v2 / RMCP+ session" (User Correctable)

Riepilogo: Unable to connect to UNITY via SSH (SSH enabled on UNITY). In order to proceed with issue analysis connection to Storage Processor via IPMI started. The IPMI connection through the service ports fails with error: Error: Unable to establish IPMI v2 / RMCP+ session ...

Questo articolo si applica a Questo articolo non si applica a Questo articolo non è legato a un prodotto specifico. Non tutte le versioni del prodotto sono identificate in questo articolo.

Sintomi

Following Dell Unity: Using the IPMI Tool on Unity Systems (User Correctable), able to ping both SPA and SPB but unable to complete the connection to Storage Processor.

IPMI fails.jpg

Causa

Wrong UNITY serial number inserted on password field ( -P xxxx ).

Risoluzione

Inserted correct UNITY Serial Number on password field ( -P xxxx ).

Prodotti interessati

Dell EMC Unity

Prodotti

Storage, Entry Level & Midrange
Proprietà dell'articolo
Numero articolo: 000194884
Tipo di articolo: Solution
Ultima modifica: 10 set 2025
Versione:  3
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.