具有用户创建的检查点的 Hyper-VM 的 RCT 备份失败,并显示“Changeblocks is not properly aligneds”
Riepilogo: 知识库文章,讨论在具有自定义创建(非 Avamar)检查点的虚拟机上 RCT 备份失败。
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
使用用户创建的(非 Avamar 创建/恢复)检查点的 Hyper-V 虚拟机备份失败,并显示类似于以下内容的错误:
avhypervvss Error : The plugin on remote client DELL1 (192.168.1.3) terminated with code 10020: completed with errors, client log should be examined avhypervvss Error : 1 remote client(s) failed to complete operation on the remote file targets avhypervvss Error : Failed to backup Virtual Machine 'EMCPC'
从 DELL1 节点:
avhypervvss Error : Changeblocks are not properly aligned to parent disk(\\?\C:\ClusterStorage\Volume6\EMCPC\EMCPC-C.VHDX). Full backup is recommended as Incremental cannot be promoted to Full at this stage of program. avhypervvss Error : Changeblocks are not properly aligned to parent disk(\\?\C:\ClusterStorage\Volume6\EMCPC\EMCPC-E.VHDX). Full backup is recommended as Incremental cannot be promoted to Full at this stage of program. avhypervvss Error : Backup extent creation failed for chain \\?\C:\ClusterStorage\Volume6\EMCPC\EMCPC-C.VHDX avhypervvss Error : Backup extent creation failed for chain \\?\C:\ClusterStorage\Volume6\EMCPC\EMCPC-E.VHDX ... avhypervvss Error : Failed to parse disk chain C:\ClusterStorage\Volume6\EMCPC\EMCPC-C.VHDX avhypervvss Error : Backup stream generator encountered an internal error. Failed to stream file '00000226\C:\ClusterStorage\Volume6\EMCPC\EMCPC-C.VHDXguid'. avhypervvss Error : Processing workorder Daily - 8_00pm to 05_59am-DR VM Group 01-1662598800011#301 (pid:3032-Hyper-V VSS) in stream mode failed.
从 winclustersvc.log 文件(位于作为 EMC 备份代理服务的活动所有者的 C:\Program Files\avs\var 文件夹中):
winclustersvc WARN: WMI API returned error: 'Failed to get the disk information. The Hyper-V Virtual Machine Management service encountered an unexpected error: There is no change tracking data available associated with the specified change tracking identifier. (0xC03A0030).' winclustersvc INFO: System.Management.ManagementException: Failed to get the disk information. The Hyper-V Virtual Machine Management service encountered an unexpected error: There is no change tracking data available associated with the specified change tracking identifier. (0xC03A0030). at EMC.BRS.HypervProxy.Common.WmiUtilities.ValidateOutput(ManagementScope scope, ManagementBaseObject outputParameters, Boolean throwIfFailed, Boolean printErrors) at EMC.BRS.WMI.Virtualization.HypervDataProvider.GetRCTExtentsforVm(String vhdPath, String RCTId, UInt64 vhdSize, HypervVm& vm, Boolean bPromoteToFullOnExtentsError)
Causa
旧热修复程序(例如 v19.4 的 #335554)中可能存在代码错误。
Risoluzione
升级到以下 Avamar 插件版本的最新热修复程序:
适用于版本 19.4.100-124 的 Avamar Hyper-V VSS 插件
热修复程序 #337450 的 337285热修复程序 #337450 适用于 Avamar Hyper-V VSS 插件
版本 19.8.100-83 的 Avamar Hyper-V VSS 插件
#337654 7.100-82 遵循戴尔知识库文章 211510, Avamar:Hyper-V VSS 插件 — 配置和安装版本 19.4 及更高版本的最新累积热修复程序,用于安装或升级最新的 Hyper-V 插件累积热修复
程序的详细过程 解决方法涉及通过 Hyper-V Manager 或 PowerShell:
https://learn.microsoft.com/en-us/virtualization/hyper-v-on-windows/user-guide/checkpoints 将检查点合并或删除回虚拟机
适用于版本 19.4.100-124 的 Avamar Hyper-V VSS 插件
热修复程序 #337450 的 337285热修复程序 #337450 适用于 Avamar Hyper-V VSS 插件
版本 19.8.100-83 的 Avamar Hyper-V VSS 插件
#337654 7.100-82 遵循戴尔知识库文章 211510, Avamar:Hyper-V VSS 插件 — 配置和安装版本 19.4 及更高版本的最新累积热修复程序,用于安装或升级最新的 Hyper-V 插件累积热修复
程序的详细过程 解决方法涉及通过 Hyper-V Manager 或 PowerShell:
https://learn.microsoft.com/en-us/virtualization/hyper-v-on-windows/user-guide/checkpoints 将检查点合并或删除回虚拟机