Embedded vApp Manager Config "Log Symmetrix Event" error "Input parameter validation failed"

Sammendrag: Embedded vApp Manager "Log Symmetrix Events" configuration error the "Input parameters validation failed"

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

When underscores are used to configure "Log Symmetrix Events" values in the Embedded vApp Manager, the following "Input Sanitization" error is observed:

Invalid Solutions Enalber Service COnfiguration value [sid=000123456789, events, array_subsystem, checksum, diagnostic, environmental, device_pool, service_processor, srdf_link, director, device, disk]

Sanitization error

Årsak

This is a known issue in the software and is planned to be addressed in a future release.

Oppløsning

The workaround is to remove the underscores from the configuration values, for example:

Invalid Solutions Enalber Service COnfiguration value [sid=000123456789, events, array subsystem, checksum, diagnostic, environmental, device pool, service processor, srdf link, director, device, disk]
Artikkelegenskaper
Artikkelnummer: 000278382
Artikkeltype: Solution
Sist endret: 15 jan. 2026
Versjon:  3
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.