PowerPath for Solaris: In an SRDF metro configuration, Proximity is not functioning.

Podsumowanie: Although "Proximity" is enabled in"powermt display options," PowerPath is not reporting the remote array as"asb:prox" and all the paths are showing "active:alive"

Ten artykuł dotyczy Ten artykuł nie dotyczy Ten artykuł nie jest powiązany z żadnym konkretnym produktem. Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.

Objawy

Environment:
DELL EMC SW: PowerPath for Solaris release 6.0 P03 hotfix 1.
DELL EMC SW: PowerPath for Solaris release 6.0 P03.
DELL EMC SW: PowerPath for Solaris release 6.0 P04.
DELL EMC SW: SRDF Metro
DELL EMC HW: VMAX3

Although "Proximity" is enabled in "powermt display options", PowerPath is not reporting the remote array as "asb:prox" and all the paths are showing "active:alive"
 
# powermt display options
    Show CLARiiON LUN names:      true
    Path Latency Monitor: Off
    Performance Monitor: disabled
    Autostandby:  Proximity       (prox): enabled
....
(S/N and FA port WWN have been changed to preserve the customer's confidentiality)
# powermt display dev=0

Pseudo name=emcpower0a
Symmetrix ID=000XXXXXXXXX  <== only 1 S/N is showing up
Logical device ID=0038
Device WWN=60000XXXXXXXXXXXXXXXXXXXXXXXXXXX
state=alive; policy=SymmOpt; queued-IOs=0
==============================================================================
--------------- Host ---------------   - Stor -  -- I/O Path --   -- Stats ---
###  HW Path               I/O Paths    Interf.  Mode     State   Q-IOs Errors
==============================================================================
3086 pci@600/pci@1/pci@0/pci@4/pci@0/pci@3/SUNW,emlxs@0/fp@0,0   c14t50000975a8134804d0s0 FA  1d:04 active   alive      0      0
3086 pci@600/pci@1/pci@0/pci@4/pci@0/pci@3/SUNW,emlxs@0/fp@0,0   c14t50000975a8134c1fd0s0 FA  1d:31 active   alive      0      0   <<< path to the remote array 297801235 is active instead of asb:prox
3087 pci@600/pci@1/pci@0/pci@4/pci@0/pci@3/SUNW,emlxs@0,1/fp@0,0 c15t50000975a8134884d0s0 FA  3d:04 active   alive      0      0
3087 pci@600/pci@1/pci@0/pci@4/pci@0/pci@3/SUNW,emlxs@0,1/fp@0,0 c15t50000975a8134c9fd0s0 FA  3d:31 active   alive      0      0   <<< path to the remote array 297801235 is active instead of asb:prox

Przyczyna

PowerPath on Solaris is not able to automatically detect sub-optimal paths to set as standby (Proximity with autostandby). After enabling autostandby and proximity, all paths (including sub-optimal) are still reported as "Active"  instead of "asb:prox"  in powermt commands.

This is working as designed. asb:prox on Solaris is available only for VPLEX geo cluster, but not for SRDF metro: This feature was made available after the latest (and final) release of PowerPath for Solaris was developed. As a consequence, it is normal to see all the devices "active" instead of "asb:prox"

Rozwiązanie

PowerPath for Solaris works as designed in an SRDF metro environment. If needed, the paths to the remote array can be set to standby with a manual command such as: 
powermt set mode=standby dev=c14t50000975a8134c1f
powermt set mode=standby dev=c30t50000975a8134c9f
In a Solaris environment, "proximity", even when enabled, is only taken into account for VPLEX, but not for VMAX SRDF metro. Since developments by Oracle have been stopped on Solaris, so were stopped the developments of new features for PowerPath on Solaris.

Produkty, których dotyczy problem

PowerPath for Solaris

Produkty

PowerPath for Solaris
Właściwości artykułu
Numer artykułu: 000058577
Typ artykułu: Solution
Ostatnia modyfikacja: 13 lis 2025
Wersja:  5
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej
Sprawdź, czy Twoje urządzenie jest objęte usługą pomocy technicznej.