Data Protection Advisor (DPA): Networker Workflow Configuration report does not populate all fields

Podsumowanie: Networker-workflow-configuration-report-does-not-populate-all-fields

Ten artykuł dotyczy Ten artykuł nie dotyczy Ten artykuł nie jest powiązany z żadnym konkretnym produktem. Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.

Objawy



When running the Networker Workflow Configuration report, some fields like the following are not populated:
  • Start Time
  • Interval
  • Restart window
  • AutoStart Enabled
The Networker Configuration request is running successfully and all other details are showing up on the reports.

Przyczyna

Data Protection Advisor is working as designed.

The Networker Configuration request did not have the "Use server REST API" option set to true.
Some details of the workflow configuration are only collected if using the above option.
This is outlined in the DPA Data Collection Reference Guide.

Rozwiązanie

Enable "Use server REST API" option on the NetWorker Configuration request with proper credentials.

Produkty, których dotyczy problem

Data Protection Advisor

Produkty

Data Protection Advisor
Właściwości artykułu
Numer artykułu: 000060394
Typ artykułu: Solution
Ostatnia modyfikacja: 27 maj 2026
Wersja:  5
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej
Sprawdź, czy Twoje urządzenie jest objęte usługą pomocy technicznej.