Objawy

vCenter-versjon: 8.0.2 build-23504390
ESXHostNVersion: 8.0.3
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.401Z DEBUG:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: vCenter SOAP call 'DpSnapshot' was accepted.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z DEBUG:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: taskInfo.Error.Fault = '*types.InvalidArgument', &{RuntimeFault:{MethodFault:{FaultCause:<nil> FaultMessage:[]}} InvalidProperty:vendorId}
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: vCenter task 'task-5759563' failed.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: Unable to create LWD snapshot.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: Unsuccessful after 41 attempts over 10m13.786743529s.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z DEBUG:  [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Snapshot failure can't be remedied by a Full sync.
Informasjonen i dpd Loggen indikerer:
2024-06-28T12:59:45.378Z Er(163) dpd[2100259]: [Originator@6876 sub=Task opID=027fa342-a343] Task 'Dp.Task.Snapshot.c9788b5a-c65c-4305-a9a2-e2a89a3d2bd7' failed with error: (vmodl.fault.InvalidArgument) {
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: -->    faultCause = (vmodl.MethodFault) null, 
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: -->    faultMessage = <unset>, 
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: -->    invalidProperty = "vendorId"
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: -->    msg = ""
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> }

Przyczyna

vCenter-versjon: 8.0.2 build-23504390
ESXi Host version: 8.0.3

vMotion-sviktende VM-er til ESXi-vert som har samme versjon eller mindre enn vCenter-versjonen.

Rozwiązanie

vCenter Server-buildnummer være samme versjon eller høyere for byggnummer for ESXi-vert. Se Broadcom-artikkelen vCenter Server-versjonen må være samme versjon eller høyere enn ESXi-vertsversjonen.  Denne hyperkoblingen tar deg til et nettsted utenfor Dell Technologies.