PowerProtect: ABV0016: VM Direct 엔진 'localhost'가 가상 머신을 백업할 수 없습니다.
Podsumowanie: ABV0016: vCenter API 문제로 인해 VM Direct 엔진 'localhost'가 vCenter 'vCenterName'에서 가상 머신 'VMName'을 백업할 수 없습니다. FaultMessage:[]}} InvalidProperty:vendorId}
Ten artykuł dotyczy
Ten artykuł nie dotyczy
Ten artykuł nie jest powiązany z żadnym konkretnym produktem.
Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.
Objawy
vCenter 버전: 8.0.2 빌드-23504390
ESXHostNVersion: 8.0.3
ESXHostNVersion: 8.0.3
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.401Z DEBUG: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: vCenter SOAP call 'DpSnapshot' was accepted.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z DEBUG: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: taskInfo.Error.Fault = '*types.InvalidArgument', &{RuntimeFault:{MethodFault:{FaultCause:<nil> FaultMessage:[]}} InvalidProperty:vendorId}
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: vCenter task 'task-5759563' failed.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: Unable to create LWD snapshot.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z ERROR: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Create LWD Snapshot: Unsuccessful after 41 attempts over 10m13.786743529s.
BackupVmSessions-48d4b7e8-5b2a-4b9c-9099-5291590fc924.log: 2024-06-28T14:26:33.706Z DEBUG: [a60fbedf3eff9dfb;aa2a835bc2e4acaa] SDM Data Mover: Snapshot failure can't be remedied by a Full sync. 비디오 dpd 로그는 다음을 나타냅니다.
2024-06-28T12:59:45.378Z Er(163) dpd[2100259]: [Originator@6876 sub=Task opID=027fa342-a343] Task 'Dp.Task.Snapshot.c9788b5a-c65c-4305-a9a2-e2a89a3d2bd7' failed with error: (vmodl.fault.InvalidArgument) {
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> faultCause = (vmodl.MethodFault) null,
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> faultMessage = <unset>,
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> invalidProperty = "vendorId"
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> msg = ""
2024-06-28T12:59:45.378Z Er(163) dpd[2100239]: --> }Przyczyna
vCenter 버전: 8.0.2 빌드-23504390
ESXi 호스트 버전: 8.0.3
vMotion이 vCenter 버전이 동일하거나 이전 버전인 ESXi 호스트에서 VM에 실패합니다.
ESXi 호스트 버전: 8.0.3
vMotion이 vCenter 버전이 동일하거나 이전 버전인 ESXi 호스트에서 VM에 실패합니다.
Rozwiązanie
vCenter Server 빌드 번호는 ESXi 호스트 빌드 번호의 버전 이상이어야 합니다. Broadcom 문서 vCenter Server 버전이 ESXi 호스트 버전과 같거나 그 이상이어야 함을 참조하십시오.

Właściwości artykułu
Numer artykułu: 000226690
Typ artykułu: Solution
Ostatnia modyfikacja: 31 lip 2024
Wersja: 2
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej