ECS: Odkaz na postup NFSv3 není podporován v požadavku ReadLinkRequest
Resumo: Chyba streamování protokolu funkce dataheadsvc: Odkaz na postup NFSv3 není podporován v požadavku ReadLinkRequest.
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
Protokol dataheadsvc streamuje následující chyby:
Command:# cat /opt/emc/caspian/fabric/agent/services/object/main/log/dataheadsvc.log
Příklad:
2018-08-16T10:13:35,312 [RpcDispatcherMD-1392] INFO COMMIT3Handler.java (line 132) Retrieved attributes for : 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240 Size : 1010564 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1441996478 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1458773694 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,317 [RpcDispatcherMD-1356-0a01821f:165323f0b49:ef:2838a52] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD 2018-08-16T10:13:35,318 [RpcDispatcherMD-1298-0a01821f:165323f0b49:e6:283489e] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD
Causa
Postup systému souborů NFS (Network File System) používaný klientskou operací je LINK, což je pevný odkaz. Tato možnost není podporována.
Resolução
NFS podporuje všechny postupy NFSv3 KROMĚ LINK: Vytvořte pevný odkaz na objekt.
Mais informações
Viz část NFS v technických častých dotazech.
Produtos afetados
Elastic Cloud StorageProdutos
Elastic Cloud StoragePropriedades do artigo
Número do artigo: 000042857
Tipo de artigo: Solution
Último modificado: 12 set. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.