Sintomas
Le journal dataheadsvc diffuse les erreurs suivantes :
Commande :# cat /opt/emc/caspian/fabric/agent/services/object/main/log/dataheadsvc.log
Exemple :
2018-08-16T10:13:35,312 [RpcDispatcherMD-1392] INFO COMMIT3Handler.java (line 132) Retrieved attributes for : 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240 Size : 1010564 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1441996478 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1458773694 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,317 [RpcDispatcherMD-1356-0a01821f:165323f0b49:ef:2838a52] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD 2018-08-16T10:13:35,318 [RpcDispatcherMD-1298-0a01821f:165323f0b49:e6:283489e] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD
Causa
La procédure NFS (Network File System) utilisée par le client est LINK, qui est un lien physique. Cette disposition n’est pas prise en charge.
Resolução
NFS prend en charge toutes les procédures NFSv3 À L’EXCEPTION DE LINK : Créer un lien physique vers un objet.
Mais informações
Reportez-vous à la section NFS de la FAQ technique.
Produtos afetados
Elastic Cloud StorageProdutos
Elastic Cloud StoragePropriedades do artigo
Número do artigo: 000042857
Tipo de artigo: Solution
Último modificado: 12 set. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.