地理位置分散的灾难重启:使用动态 REXX API 发出 SRDF-HC 命令时,GDDR 无法识别非零返回代码
Resumo: 使用动态 REXX API 发出主机组件命令时,GDDR 无法识别非零返回代码。
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
如果 SRDF 主机组件命令在 GDDR 脚本期间失败,消息GDDR313I可能会错误地指示 RC=0(如下例),脚本可以继续,就像命令成功一样。
GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
Causa
这是软件问题。
Resolução
解决方案:
- 对于 GDDR 6.0,PTF GD60021解决了此问题。可从 Dell 在线支持下载。
- 对于 GDDR 5.3,PTF GD53104解决了此问题。可从 Dell 在线支持下载。
Mais informações
PTF 封面说明:
- GDDR 6.0L
++PTF(GD60021) REWORK(2023160) . ++VER(Z038) FMID(GDDR600) PRE( GD60014 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * * PROBLEM FIXED: GDDR-3601 * USERS AFFECTED: GDDR VMAX/PowerMax users * PROBLEM DESCRIPTION: GDDR script may not recognize non-zero * return code from SRDF HC command * * DESCRIPTION DETAIL: * * If an SRDF Host Component command fails during a GDDR * script, message GDDR313I could incorrectly indicate RC=0 * (example below) and the script could proceed as if the * command was successful. * * GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498 * * PROBLEM RESOLUTION: * * If an SRDF Host Component command fails during a GDDR * script, the return code will now be displayed correctly in * the GDDR313I message, and the script will handle the failure * as appropriate. * * In addition, message GDDR313I has been enhanced to avoid any * confusion as to what return code is displayed. Instead of * always indicating 'EMCSRDFR RC=', the message will now * indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=', * or 'IRXEXCOM RC=' so it is clear exactly which return code * is displayed. * * MODULES: GDDRDAP4 * GDDRMTXT * * ------------------------------------------------------------
- GDDR 5.3
++PTF(GD53104) REWORK(2023088) .
++VER(Z038) FMID(GDDR530)
PRE(
GD53096
)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3602
* USERS AFFECTED: GDDR VMAX/PowerMax users
* PROBLEM DESCRIPTION: GDDR script may not recognize non-zero
* return code from SRDF HC command
*
* DESCRIPTION DETAIL:
*
* If an SRDF Host Component command fails during a GDDR
* script, message GDDR313I could incorrectly indicate RC=0
* (example below) and the script could proceed as if the
* command was successful.
*
* GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
*
* PROBLEM RESOLUTION:
*
* If an SRDF Host Component command fails during a GDDR
* script, the return code will now be displayed correctly in
* the GDDR313I message, and the script will handle the failure
* as appropriate.
*
* In addition, message GDDR313I has been enhanced to avoid any
* confusion as to which return code is displayed. Instead of
* always indicating 'EMCSRDFR RC=', the message will now
* indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=',
* or 'IRXEXCOM RC=' so it is clear exactly which return code
* is displayed.
*
* MODULES: GDDRDAP4
* GDDRMTXT
*
* ------------------------------------------------------------
* GD53104 29 Mar 2023 14:49:11
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* GDDR-3602
*
*------------------------------------------------------------- Produtos afetados