PowerStore: I/O error observed on NVMe datastore during NDU
Resumo: ESXi host running 8.0 U1 using NVMe/FC and NVMe/TCP datastore may experience I/O errors during PowerStore node reboots/failures.
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
Symptoms:
Environment:
- Hosts connected using NVMe/FC or NVMe/TCP may experience I/O errors during node reboots or NDU.
Environment:
- ESXi Host 8.0 U1 is connected to PowerStore volumes/vVols.
- Host is connected using NVMe/FC or NVMe/TCP.
Causa
This is a VMware regression issue introduced in ESXI version 8. 0 U1. In this release, ESXi introduced a Native NVMe stack (aka E2E NVMe stack). Certain error codes that had a retry in previous versions of ESXI no longer have a retry applied. As a result the end applications may experience I/O failures.
Resolução
Upgrade ESXI to version 8.0 U1c or later.
Mais informações
VMware KB Article: Rebooting the storage node on the target side may affect VM IOs using the vVOL datastore. (94106)
Produtos afetados
PowerStorePropriedades do artigo
Número do artigo: 000216664
Tipo de artigo: Solution
Último modificado: 14 jun. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.