Data Domain: NVRAM Hardware Failure Alert | EVT‑NVRAM‑00201

Summary: This article describes the conditions that trigger the 'NVRAMHardwareFailure' alert on Data Domain systems and outlines the required resolution steps.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

A Critical alert is generated indicating an NVRAM hardware failure. When this alert is present:

  • The NVRAM card is considered unusable or unreliable.
  • The Data Domain file system cannot be accessed until the issue is corrected.
  • System operation may be blocked or degraded.

Alert Details:

  • Alert ID: EVT‑NVRAM‑00201
  • Severity: Critical
  • Class: hardwareFailure
  • Object: Slot=%s
  • Message:
    “A hardware fault was detected with an NVRAM card and it may need to be replaced.”

Applies to:

  • All Data Domain systems
    • For systems (DD9910,DD9410, DD6410, DD9910F) with Software Defined Persistent Memory (SDPM) See KB: Data Domain: How to Diagnose and Resolve SDPM | NVRAM Alerts  
      • SDPM-NVRAM errors also trigger the DDOS NVRAM-00201 Alert - analysis into the related iDRAC error code is required (part replacement may not be needed).
  • All Software/DDOS versions

Cause

The NVRAMHardwareFailure alert is triggered when the system detects a hardware condition that renders the NVRAM card unusable. These conditions fall into two categories:

  1. Configuration issues detected during system boot
  2. Hardware component failures detected during boot or normal operation

If multiple failures are detected simultaneously, the alert reports:
"Multiple NVRAM hardware failures."

Examples of conditions that may trigger this alert include (but are not limited to):

  • NVRAM card not detected
  • Unsupported or mixed NVRAM card types
  • Incorrect number of NVRAM cards for the platform
  • NVRAM card and DDR model mismatch
  • Inability to retrieve NVRAM card or battery information
  • Excessive correctable or uncorrectable NVRAM memory errors
  • NVRAM device operating in read‑only mode
  • Incorrect NVRAM memory size, PCIe link speed, or link width
  • Critical voltage rail conditions affecting NVRAM components

Specific failure details are provided in the alert field:
Info: Cause=%s

Resolution

  1. Run offline diagnostics or system healthcheck to confirm the NVRAM failure.
    • Useful Commands:
      • # alerts show current
      • # system show nvram
      • # support healthcheck hardware | # system health check
      • # system show hardware
  2. Correct any placement or configuration issues if applicable.
  3. If the NVRAM is PCIe-based (All-in-one) - replace the NVRAM card if diagnostics confirm a hardware failure.

If assistance is required, contact your contracted support provider - Dell Tech Support

Produse afectate

Data Domain

Produse

Data Domain
Proprietăți articol
Article Number: 000011063
Article Type: Solution
Ultima modificare: 27 Jul 2026
Version:  7
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.