Symptoms
Switch rebooted unexpectedly. Post which both the CPs were enabled and HA was synchronized.
Found that CP in slot-7 was faulted from the emtraceshow2 output.
There is a single FLT (fault) listed there for slot 7. There is no other indication of any other problem.
Fabric OS: v8.2.3c /fabos/cliexec/hadump: Local CP (Slot 6, CP0): Active, Cold Recovered Remote CP (Slot 7, CP1): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized errdump : [HAM-1004], SLOT 7 | CHASSIS, INFO, Processor rebooted - Reset., reboot.c [PLAT-5067], SLOT 7 | CHASSIS, INFO, Disabling PCI timeout detect. Rev 4, modular_proc.
Found that CP in slot-7 was faulted from the emtraceshow2 output.
NOTE: There is a root level command called EMTRACESHOW2. It is part of the supportsave and shows the components starting up after a reboot.
There is a single FLT (fault) listed there for slot 7. There is no other indication of any other problem.
/fabos/cliexec/emtraceshow2: Object Before SCN Send After privSt m fo date/time Slot 7 IN(20000) FLT(10014) ---------- IN(20000) 000000 1 0 Jan 29 14:20:51 CP BLADE Slot: 7 Header Version: 2 Power Consume Factor: -40W Factory Part Num: 60-1000376-10 Factory Serial Num: xxxxx Manufacture: Day: 16 Month: 6 Year: 2012 Update: Day: 1 Month: 2 Year: 2023 Time Alive: 3742 days Time Awake: 3 days
Cause
Hardware failure
Resolution
Fix:
1) Reseat the Standby CP which is at Slot 7. It would then go through POST and recover from the error state.
2) If reseat of CP Blade does not solve the issue, replace the CP Blade.
1) Reseat the Standby CP which is at Slot 7. It would then go through POST and recover from the error state.
2) If reseat of CP Blade does not solve the issue, replace the CP Blade.
Produse afectate
Connectrix ED-DCX8510-8BProduse
Connectrix B-SeriesProprietăți articol
Article Number: 000210195
Article Type: Solution
Ultima modificare: 16 May 2026
Version: 6
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.