PowerProtect: Unable to Discover a vCenter Discovery Job, Error: 500

Summary: PowerProtect Data Manager OS unable to discover a vCenter. Discovery Job Error: 500 unable to find a valid certification path to the requested target.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Discovery Job Error: 500 : "{"code":500,"reason":"Failed to connect to <PPDM FQDN>: HTTP transport error: javax.net.ssl.SSLHandshakeException: 
PKIX path building failed: sun.security.provider.certpath.SunCertPathBuilderException: Unable to find valid certification path to requested target","remediation":null,"timestamp":1723825208953,"path":"/api/v2/vmwareservice/vcenters/validate-connection","extendedInfo":null}".

Cause

Certificate expired

Resolution

  1. Connect to the PowerProtect Data Manager Management IP using SSH.
    1. Go through /var/log/brs/vmdm
    2. Check on the logs: vmdm-discovery.log <unable to find valid certification path to requested target>
  2. Connect to the PowerProtect Data Manager Management IP using a web browser.
    1. Go through Administration > Certificates, on the right panel check if there are Certificates Expired.
    2. Select the Expired Certificate, then click Regenerate Certificates
  3. Go to Infrastructure > Asset Sources, select the vCenter Name then click Discovery
  4. Go to Jobs > System Jobs, check the process of Manual Discovery

Produse afectate

Data Protection Suite, PowerProtect Data Protection Appliance, PowerProtect Data Manager Appliance