Data Domain: Identifying a Defective or Inactive Link Controller Card (LCC)

Zhrnutie: This article outlines the steps to determine whether a Link Controller Card (LCC) in a Dell Data Domain system is functioning correctly. A faulty LCC can lead to degraded performance, loss of path redundancy, and various system alerts. ...

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

Applies to:

  • Data Domain systems with external storage shelves (ES30 or DS60)
  • All DDOS software releases

Symptoms of a defective or inactive LCC can result in:

  • Loss of multipath connectivity to enclosures
  • Alerts indicating only one active path (instead of two)
  • Disks reported as absent, failed, unknown, or degraded
  • Irregular or unexpected link speeds on HOST or EXP'N ports
  • Missing SAS paths to multiple enclosures
  • Filesystem down due to missing disk groups
 

Príčina

Common causes for LCC or SAS (MPATH) issues are:

  • Hardware failure (LCC, SAS cable, HBA)
  • Improper cabling or loose connections
  • Power issues with the enclosure
  • Firmware or software anomalies
  • Site maintenance or upgrade activities

Riešenie

1. Check System Alerts:

  • Run:
  • # alerts show current

Review for disk or enclosure-related alerts that may indicate SAS connectivity issues.

2. Verify SAS Topology:

  • Run:
  • # enclosure show topology

kA2j0000000R14ECAS_1_0

Look for question marks (???) between enclosure paths, which indicate a possible fault in the controller or cabling.

Example Output:

Port      enc.ctrl.port             enc.ctrl.port           enc.ctrl.port
3a    >    5.A.H:5.A.E    ?  ?  ?    7.B.H:7.B.E      >      6.B.H:6.B.E
Error Message:
? - A possible problem was detected for this shelf controller or the cable connected to it.

If ??? is present:

    • Physically inspect and reseat SAS cables between shelves.
    • If cables are secure and alerts persist, escalate to Support.

3. Check LCC Status and Link Speeds:

  • Run:
  • # enclosure show controllers <Enclosure_Number>

Example Output (DS60):

  • Encl 2
      Model                   DS60
      Capacity                60 Slots
      WWN                     N/A
      Serial #                JWXCD134400059
      Number of Controllers   2
    
      Controller A
        WWN          500604811015F07F
        Firmware     2.10.1
        Serial #     JWXCL134300134
        Status       OK
        HOST port    24.0 Gbps
        EXP'N port   48.0 Gbps
    
      Controller B
        WWN          500604811007517F
        Firmware     2.10.1
        Serial #     JWXCL134200021
        Status       OK
        HOST port    48.0 Gbps
        EXP'N port   0.0 Gbps

Example Output (ES30):

  • Encl 3
      Model                   ES30
      Capacity                15 Slots
      WWN                     N/A
      Serial #                APM00134300555
      Number of Controllers   2
    
      Controller A
        WWN          50060480062C7CBF
        Firmware     1.55
        Serial #     CF23V132500362
        Status       OK
        HOST port    24.0 Gbps
        EXP'N port   24.0 Gbps
    
      Controller B
        WWN          50060480062D79BF
        Firmware     1.55
        Serial #     CF23V132500867
        Status       OK
        HOST port    24.0 Gbps
        EXP'N port   0.0 Gbps

Expected Link Speeds:

    • ES30: All links = 24.0 Gbps
    • DS60:
      • HBA to HOST port = 24.0 Gbps
      • Shelf-to-shelf EXP'N port = 48.0 Gbps
      • 0.0 Gbps indicates no physical link

Status: Should be OK
Firmware/Serial #: Blank fields may indicate a faulty LCC.

4. Physical Inspection

  • Check for amber LEDs on the enclosure or LCC
  • Ensure that AC power is connected and the shelf is powered on

5. Escalation

If the issue persists after basic troubleshooting:

  • Generate a Support Bundle
  • Raise a Service Request with your contracted Support Provider

Ďalšie informácie

Dotknuté produkty

Data Domain

Produkty

Data Domain, Data Domain Deduplication Storage Systems, DS60, ES30
Vlastnosti článku
Číslo článku: 000032863
Typ článku: Solution
Dátum poslednej úpravy: 07 okt 2025
Verzia:  3
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.