NetWorker VMware Protection vProxy: VM snapshot creation incomplete: An error occurred while taking a snapshot: Invalid change tracker error code
Zhrnutie: Dell NetWorker vProxy backup for a VM fails due to failing VMware snapshot. ERROR: Snapshot creation task failed: An error occurred while taking a snapshot: Invalid change tracker error code ...
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
VM backups performed through the NetWorker VMware Protection (NVP) vProxy appliance fail
The vProxy log reports:
The vProxy log reports:
/opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-snapmgr.log
2023-02-28T01:24:10Z INFO: Connected to session on vCenter 'vcenter.local' Version '7.0.3 build-20845200, API:7.0.3.0', Uuid:#.
2023-02-28T01:24:10Z INFO: Creating snapshot type 'COPY' with timeout of 30 minutes ...
2023-02-28T01:24:10Z NOTICE: Snapshot free space threshold validation not requested.
2023-02-28T01:24:10Z INFO: Found virtual machine 'VMname' with MORef 'vm-#'.
2023-02-28T01:24:10Z INFO: Host 'esxihost.local' is running 7.0.3.
2023-02-28T01:24:10Z INFO: host version 7.0.3:true
2023-02-28T01:24:11Z ERROR: Snapshot creation task failed: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z ERROR: Unable to create quiesced snapshot: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z NOTICE: Snapshot free space threshold validation not requested.
2023-02-28T01:24:11Z WARN: Retrying as a non-quiesced snapshot: Unable to create quiesced snapshot: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z INFO: Task to create snapshot completed, errors = true.
2023-02-28T01:24:11Z ERROR: Unable to create non-quiesced snapshot after a retry attempt: An error occurred while taking a snapshot: Invalid change tracker error code.
2023-02-28T01:24:11Z INFO: Disconnected from session on vCenter 'vCenter.local'.Príčina
A manual attempt to take a snapshot of the VM is failing within vCenter.
Riešenie
Workaround:
- vMotion the VM to another ESXi host.
- Run the manual snapshot again.
- Once a manual snapshot succeeds, the VM backup on the vProxy progresses
Overview of virtual machine snapshots in vSphere (1015180): https://kb.vmware.com/s/article/1015180
Ďalšie informácie
Dotknuté produkty
NetWorkerProdukty
NetWorker Family, NetWorker SeriesVlastnosti článku
Číslo článku: 000210940
Typ článku: Solution
Dátum poslednej úpravy: 16 aug 2026
Verzia: 6
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.