Connectrix MDS: Falha no upgrade no MDS 9706 ou 9710 com o erro "bootflash busy; seg fault while mounting bootflash"

摘要: O usuário não consegue mais ver "bootflash://sup-standby" após o upgrade do NX-OS 6.2.19 para o 8.1.1.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Fazendo upgrade do NX-OS 6.2.19 para o 8.1.1.

Após o upgrade, o usuário não poderá mais ver "bootflash://sup-standby".

Visto da seguinte forma:
MDS1# dir bootflash:
bootflash:///
bootflash://module-5/
bootflash://sup-1/
bootflash://sup-active/
bootflash://sup-local/ 
Um switch em funcionamento mostra o seguinte:
MDS2# dir bootflash:
bootflash:///
bootflash://module-6/
bootflash://sup-2/
bootflash://sup-local/
bootflash://sup-standby/
bootflash://module-5/
bootflash://sup-1/
bootflash://sup-active/
bootflash://sup-remote/    <---------------
Outros sintomas do problema podem ser:
  • O ISSU/D falha com a seguinte mensagem de erro:
Pre-upgrade check failed. Return code 0x4093007E (Issue cannot be done, bootflash is busy). 'segmentation fault' error messages when issuing `sys health check bootflash`:

switch# sys health check bootflash Unmount successful... Checking any file system errors...Please be patient... /isanboot/sbin/format-bootflash: line 75: 7598 Segmentation fault $SUDO $E2FSCK -n -v $@ > /dev/null 2> /dev/null done. 
Remounting bootflash .../isanboot/sbin/format-bootflash: line 62: 7600 Segmentation fault $SUDO /bin/mount $MNT_BOOTFLASH_DIR Failed to mount bootflash bootflash on the affected supervisor is not available switch# dir no such file or directory (invalid server) 
Logging log outputs: %BOOTVAR-2-AUTOCOPY_STANDBY_MOUNT_FAILED: Autocopy failed to access standby file system via NFS mount.Please, copy the boot images manually to standby bootflash. %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 6688 with message non-sysmgr(non-sysmgr) crashed, core will be saved . Core file also generated: 
`show cores` Module  Instance  Process-name     PID       Date(Year-Month-Day Time) ------  --------  ---------------  --------  ------------------------- 5       1         non-sysmgr       6688      2017-10-08 07:29:07

原因

O problema é identificado como o seguinte no Cisco CSCvb93701:
ISSU/D fails on MDS 9706/9710 with 'bootflash busy' error; seg fault while mounting bootflash
CSCvb93701 (see also CSCvf99665)
De acordo com o problema documentado da Cisco:
The system is only affected if it was previously running one of the following NX-OS releases: 6.2(17) - 6.2(19) 7.3(0)D1(1) - 7.3(1)D1(1) 7.3(0)DY(1) - 7.3(1)DY(1) This issue does not apply to any other NX-OS releases on MDS 9706 and 9710 platforms. It does not occur on the MDS 9718 platform.

解决方案

Solução alternativa:
A sub-rede inválida IPv6 na interface de gerenciamento causa esse problema.
switch13# show interface mgmt0
mgmt0 is up
    Hardware is GigabitEthernet
    Address is 2cab.ebfd.4386
    Internet address(es):
        10.8.96.223/23
        ::148.125.166.255/0      <--- "0" indicates an invalid subnet
        fe80::2eab:ebff:fefd:4386/64

Entre em contato com o suporte técnico da Dell para obter assistência na recuperação.

受影响的产品

Connectrix MDS-9710

产品

Connectrix MDS-9706, Connectrix MDS-9710
文章属性
文章编号: 000052402
文章类型: Solution
上次修改时间: 21 9月 2023
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。