Connectrix MDS: Failed Upgrade on MDS 9706 or 9710 with Error "bootflash busy; seg fault while mounting bootflash"
摘要: User is no longer able to see "bootflash://sup-standby" after upgrading from NX-OS 6.2.19 to 8.1.1.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
Upgrading from NX-OS 6.2.19 to 8.1.1.
After upgrade, user is no longer able to see "bootflash://sup-standby."
Seen as follows:
A working switch shows the following:
Other symptoms of the issue can be the following:
After upgrade, user is no longer able to see "bootflash://sup-standby."
Seen as follows:
MDS1# dir bootflash: bootflash:/// bootflash://module-5/ bootflash://sup-1/ bootflash://sup-active/ bootflash://sup-local/
MDS2# dir bootflash: bootflash:/// bootflash://module-6/ bootflash://sup-2/ bootflash://sup-local/ bootflash://sup-standby/ bootflash://module-5/ bootflash://sup-1/ bootflash://sup-active/ bootflash://sup-remote/ <---------------
- ISSU/D fails with the following error message:
Pre-upgrade check failed. Return code 0x4093007E (Issue cannot be done, bootflash is busy). 'segmentation fault' error messages when issuing `sys health check bootflash`: switch# sys health check bootflash Unmount successful... Checking any file system errors...Please be patient... /isanboot/sbin/format-bootflash: line 75: 7598 Segmentation fault $SUDO $E2FSCK -n -v $@ > /dev/null 2> /dev/null done. Remounting bootflash .../isanboot/sbin/format-bootflash: line 62: 7600 Segmentation fault $SUDO /bin/mount $MNT_BOOTFLASH_DIR Failed to mount bootflash bootflash on the affected supervisor is not available switch# dir no such file or directory (invalid server) Logging log outputs: %BOOTVAR-2-AUTOCOPY_STANDBY_MOUNT_FAILED: Autocopy failed to access standby file system via NFS mount.Please, copy the boot images manually to standby bootflash. %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 6688 with message non-sysmgr(non-sysmgr) crashed, core will be saved . Core file also generated: `show cores` Module Instance Process-name PID Date(Year-Month-Day Time) ------ -------- --------------- -------- ------------------------- 5 1 non-sysmgr 6688 2017-10-08 07:29:07
原因
The issue is identified as the following from Cisco CSCvb93701:
As per the documented Cisco issue:
ISSU/D fails on MDS 9706/9710 with 'bootflash busy' error; seg fault while mounting bootflash CSCvb93701 (see also CSCvf99665)
The system is only affected if it was previously running one of the following NX-OS releases: 6.2(17) - 6.2(19) 7.3(0)D1(1) - 7.3(1)D1(1) 7.3(0)DY(1) - 7.3(1)DY(1) This issue does not apply to any other NX-OS releases on MDS 9706 and 9710 platforms. It does not occur on the MDS 9718 platform.
解决方案
Workaround:
The IPv6 invalid subnet on the management interface causes this issue.
Contact Dell Technical Support for assistance to recover.
The IPv6 invalid subnet on the management interface causes this issue.
switch13# show interface mgmt0
mgmt0 is up
Hardware is GigabitEthernet
Address is 2cab.ebfd.4386
Internet address(es):
10.8.96.223/23
::148.125.166.255/0 <--- "0" indicates an invalid subnet
fe80::2eab:ebff:fefd:4386/64
Contact Dell Technical Support for assistance to recover.
受影响的产品
Connectrix MDS-9710产品
Connectrix MDS-9706, Connectrix MDS-9710文章属性
文章编号: 000052402
文章类型: Solution
上次修改时间: 21 9月 2023
版本: 4
从其他戴尔用户那里查找问题的答案