Deployment KB: Unable to power on the VM on ESXi host in the CR Vault
摘要: During VM restore inside the cyber vault, VM restore failed to power on.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
In the /var/log/vmware.log file, similar entries to the below are seen:
Note: The log excerpts are examples. Date, time, and environmental variables may vary depending on the environment.
Unable to create virtual scsi0:0.filters="esx_splitter",
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
原因
Production VM protected using RP4VM may cause issues after restore inside the vault.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.
解决方案
To resolve this issue, follow the steps below:
- Connect to the ESXi host the virtual machine is on using SSH and root credentials
- Navigate to the virtual machines .vmx file using this command:
cd /vmfs/volumes/datastore/virtual_machine_folder/
- Open the .vmx file with a text editor: vi virtual_machine.vmx
- Add a # before any filters that contain scsi0:0.filters="esx_splitter"
- Save the changes and exit the text editor.
- Power on the virtual machine.
受影响的产品