Deployment KB: Unable to power on the VM on ESXi host in the CR Vault

摘要: During VM restore inside the cyber vault, VM restore failed to power on.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

In the /var/log/vmware.log file, similar entries to the below are seen:    
Unable to create virtual scsi0:0.filters="esx_splitter",
Failed to attach filter scsi0:0.filters="esx_splitter": Not found.
error.jpg
Note: The log excerpts are examples. Date, time, and environmental variables may vary depending on the environment.
 

原因

Production VM protected using RP4VM may cause issues after restore inside the vault. 

This issue usually occurs if there is a splitter installed on the source ESXi host which is not present on the destination ESXi host.

解决方案

To resolve this issue, follow the steps below:     
  1. Connect to the ESXi host the virtual machine is on using SSH and root credentials
  2. Navigate to the virtual machines .vmx file using this command:      
cd /vmfs/volumes/datastore/virtual_machine_folder/
  1. Open the .vmx file with a text editor: vi virtual_machine.vmx
  2. Add a # before any filters that contain scsi0:0.filters="esx_splitter"
  3. Save the changes and exit the text editor.
  4. Power on the virtual machine.

受影响的产品

Avamar, Cyber Recovery Series, VMware ESXi 6.x

产品

VMware ESXi 6.5.X, VMware ESXi 6.7.X, VMware ESXi 7.x