SCv3000 Series (Compellent) Reference Articles
摘要: A guide to the SCv3000 Dell EMC Storage unit. There are sections on General Overview, Getting Started, Troubleshooting and SCOS information. The SCv3000 provides more capacity and greater flexibility as you manage a variety of workloads. Realize rack space savings with a 3U with the SC300 and SC320 and SC360 expansion enclosures ...
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
Support Library - SCv3000 Series (Compellent)
Product Overview:
The SCv3000 Series base array is available in two 3U "all-in-one" configurations, the SCv3000 and SCv3020. Both models include dual controllers with 6-core Intel processors, 32GB memory (16GB per controller) and flexible 10Gb iSCSI, 12Gb SAS or 16Gb FC network connections.
Optional expansion enclosures let you scale up to 222 drives, or 1PB per array* – with even larger scale-out potential in federated multi-array systems. All three expansion enclosures may be used with either base array. All array and expansion enclosure models support a variety of SSD, 15K, 10K and NLSAS drives (including FIPS-certified SEDs).
Note: Some documents are only available in English.
General overview:
Getting Started:
- SCv3000 Series Installation Video
- SC Storage Customer Notification: How to apply Host Server Best Practice settings using the Dell Storage Manager Client
- Preparing VMWare ESXi Hosts to attached to SCv20x0, SCv30x0, SC4020, SC5020 SAS Arrays
- Dell EMC SC Series Storage and Microsoft Multipath I/O
- Dell EMC SC Series and Active Directory Integration
- Dell SC Series Storage with SAS Front-end Support for VMWare vSphere
- Citrix XenServer with Dell SC Series Storage configuration and Deployment
- Deploying SharePoint 2016 utilizing Dell Storage SC Series Arrays
Troubleshooting:
- Drivers and Downloads
- SC Storage Customer Notification: Dell Storage Manager server setup fails with Error Turning on MPIO
- SC Storage Customer Notification: SCv3000, SC5020 and SC7020 systems do not retain iDRAC Email Alert Information
- SC Storage Customer Notification: Deduplication Operation can result in unexpected system behavior
- SC Storage Customer Notification: Troubleshooting DSM "Error setting up connection" Message During Initial Deployment
System Software:
Storage Enclosures:
- For information on Dell EMC SC Series Expansion Enclosures Click here
- Dell EMC SCv300 and SCv320 Expansion Enclosure Owner's Manual
- Dell EMC SCv360 Expansion Enclosure Owners Manual
原因
解析度
受影響的產品
Dell Storage SCv300, Dell Storage SCv3000, Dell Storage SCv3020, Dell Storage SCv320, Dell Storage SCv360文章屬性
文章編號: 000178226
文章類型: Solution
上次修改時間: 06 5月 2026
版本: 8
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。