Removing The SAS Chain Cable(s)

  • CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
  1. Remove the cooling fan module from one side on the back of the chassis.
    • CAUTION: If you are hot swapping the SAS cable chains, ensure that you complete the procedure on one side within ten minutes to avoid over heating of the storage enclosure.
    • CAUTION: Ensure that you are removing the SAS cable chain for the failed physical-disk drawer. Removing the SAS cable chain for the incorrect physical-disk drawer causes loss of data access and causes virtual disks to appear degraded in the MD Storage Manager.
  2. Locate and identify the SAS chain cables for the failed physical-disk drawer.
  3. To remove the chain cable mounting bracket from the midplane, insert your finger into the release tab (oriented vertically), and pull the mounting bracket completely out of the storage enclosure.
  4. To remove the chain cable mounting bracket from the physical disk drawer, insert your finger into the release tab (oriented horizontally), and pull the mounting bracket completely out of the storage enclosure.
  5. Install the cooling fan module.
  6. Repeat the above mentioned steps for the SAS cable chain on the other side.
    Figure 1. Removing and Installing the SAS Chain Cable(s) This figure shows the removing and installing of the SAS chain cable(s).
    1. left cooling fan module bay
    2. right cooling fan module bay
    3. SAS cable connector on the midplane (two per physical disk drawer)
    4. SAS cable connector to the midplane (oriented vertically)
    5. SAS chain cable (two per physical disk drawer)
    6. release tab (oriented horizontally)
    7. SAS cable connector to the physical-disk drawer (oriented horizontally)
    8. SAS cable connector on the physical-disk drawer (oriented horizontally)