Dell Chassis Management Controller Version 3.10 for Dell EMC PowerEdge VRTX User's Guide

Configuring iDRAC Virtual LAN Tag Settings Using RACADM

  • Specify the Virtual LAN ID and priority of a particular server with the following command:
    racadm setniccfg -m server-<
                                           n> -v <
                                           VLAN id> <
                                           VLAN priority>
                                        

    The valid values for < n> are 1–4.

    The valid values for < VLAN> are 1–4000 and 4021–4094. Default is 1.

    The valid values for < VLAN priority> are 0–7. Default is 0.

    For example:
    racadm setniccfg -m server-1 -v 1 7
    For example:
    
                                           
                                        
  • To remove a server VLAN, disable the VLAN capabilities of the specified server's network:
    racadm setniccfg -m server-<
                                           n> -v
                                        

    The valid values for < n> are 1–4.

    For example:
    racadm setniccfg -m server-1 -v