Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.10 for Dell EMC PowerEdge VRTX User's Guide

Conversion of External Shared PERC 8 card Non-High Availability to High Availability Mode using RACADM

Dell PowerEdge VRTX chassis must have External Shared PERC 8 cards in PCI slot 5 and PCI slot 6.

Workflow

  1. Power down chassis. Disconnect all SAS cables from External Shared PERC 8 cards to MD12x0 enclosures.
  2. Power Up chassis.
  3. Login to CMC Racadm and run the following command when the servers are in powered off state:

    racadm raid set controllers:RAID.ChassisSlot.5-1 –p HighAvailabilityMode ha
  4. Run the command racadm raid set controllers:RAID.ChassisSlot.6-1 –p HighAvailabilityMode ha on External Shared PERC 8 card in slot 6.
  5. Resetting both the PERCs may take two minutes to reflect in HA mode.
  6. Power down chassis and connect the enclosures in HA Mode.
  7. Power Up chassis.
  8. External Shared PERC 8 card is in HighAvailabiltiy Mode and the HA status is seen by using the following command:
    racadm raid get controllers -o -p HighAvailabilityMode
    .

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\