Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.10 for Dell EMC PowerEdge VRTX User's Guide

Conversion of External Shared PERC 8 card High Availability to Non-High Availability Mode using Web Interface

Dell PowerEdge VRTX chassis must have 2 External Shared PERC 8 cards in PCI slot 5 and PCI slot 6 in HA mode.

Workflow

  1. Power down chassis. Disconnect all SAS cables from External Shared PERC 8 cards to MD12x0 enclosures.
  2. Power Up chassis.
  3. Login to CMC web interface and navigate to the Storage → Controllers → Troubleshooting and disable Fault tolerance from the drop-down menu for External Shared PERC 8 card in slot 5, click Apply and select disable for slot 6, and then click Apply.

  4. Resetting both the PERCs may take two minutes to reflect in Non-HA mode.
  5. Power down chassis and connect the enclosures in Non-HA Mode.
  6. Power Up chassis.
  7. External Shared PERC 8 card is not in HighAvailabiltiy Mode and navigate to Storage → Troubleshooting → Setup Troubleshooting to view the Non-HA status.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\