drawers

This basetype is used by show enclosures.

Table 1. drawers properties
Name Type Description
durable-id string Drawer ID.
drawer-id

(5U84 enclosure)

uint8
  • 0: Top
  • 1: Bottom
drawer-id

(2U12/24 enclosure)

uint8 Not applicable (255).
drawer-wwn string Drawer WWN.
part-number string Drawer part number.
name string Drawer name.
position string The drawer position in the enclosure, as viewed from the front.
  • Left
  • Right
  • Top
  • Bottom
position-numeric uint32 Numeric equivalents for position values.
  • 0: Left
  • 1: Right
  • 2: Top
  • 3: Bottom
rows uint8 Number of rows of disk slots.
columns uint8 Number of columns of disk slots.
slots uint8 Number of disk slots in drawer.
number-of-disks uint8 Number of disk slots (not installed disks) in drawer.
emp-a-busid string SCSI channel ID of Enclosure Management Processor (EMP) A in the Expander Controller of a drawer.
emp-a-targetid string SCSI target ID of Enclosure Management Processor (EMP) A in the Expander Controller of a drawer.
emp-a-rev string Firmware revision of Enclosure Management Processor (EMP) A in the Expander Controller of a drawer.
emp-b-busid string SCSI channel ID of Enclosure Management Processor (EMP) B in the Expander Controller of a drawer.
emp-b-targetid string SCSI target ID of Enclosure Management Processor (EMP) B in the Expander Controller of a drawer.
emp-b-rev string Firmware revision of Enclosure Management Processor (EMP) B in the Expander Controller of a drawer.
emp-a string Shows the field name EMP A in console format.
emp-a-ch-id-rev string Channel ID and firmware revision of Enclosure Management Processor A in the Expander Controller of a drawer.
emp-b string Shows the field name EMP B in console format.
emp-b-ch-id-rev string Channel ID and firmware revision of Enclosure Management Processor B in the Expander Controller of a drawer.
locator-led string Shows the state of the locator LED on a drawer:
  • Off
  • On
locator-led-numeric uint32

Numeric equivalents for locator-led values.

  • 0: Off
  • 1: On
status string Drawer status.
  • Unsupported
  • OK
  • Critical
  • Warning
  • Unrecoverable
  • Not Installed
  • Unknown
  • Unavailable
status-numeric uint32 Numeric equivalents for status values.
  • 0: Unsupported
  • 1: OK
  • 2: Critical
  • 3: Warning
  • 4: Unrecoverable
  • 5: Not Installed
  • 6: Unknown
  • 7: Unavailable
extended-status hex32 A numeric value that supplements the standard SES status shown by the status and status-numeric properties, and represents a specific condition.
health string
  • OK
  • Degraded
  • Fault
  • N/A
  • Unknown
health-numeric uint32 Numeric equivalents for health values.
  • 0: OK
  • 1: Degraded
  • 2: Fault
  • 4: N/A
health-reason string If Health is not OK, the reason for the health state.
health-recommendation string If Health is not OK, the recommended actions to take to resolve the health issue.
unhealthy component Embedded; see unhealthy-component.
sideplane-details Embedded; see sideplanes.