This basetype is used by show sas-link-health.

Table 1. expander-ports properties
Name Type Description
durable-id string Expander port ID.
enclosure-id uint32 Enclosure ID.
controller string
  • A: Controller A.
  • B: Controller B.
controller-numeric uint32 Numeric equivalents for controller values.
  • 0: B
  • 1: A
sas-port-type string
  • Drawer Port Egress
  • Drawer Port Ingress
  • Expansion Port Egress
  • Expansion Port Ingress
  • Expansion Port Universal
sas-port-type-numeric uint32 Numeric equivalents for sas-port-type values.
  • 1: Drawer Port Egress
  • 2: Drawer Port Ingress
  • 3: Expansion Port Egress
  • 4: Expansion Port Ingress
  • 5: Expansion Port Universal
sas-port-index uint32 The expander port index. For an IOM with two expansion ports, this value differentiates the two egress ports (0–1) and two ingress ports (0–1) for each path A and B. This value is appended to the port’s durable-id value.
name string
  • Out Port: Egress (expansion) port on controller module or an expansion module. Can be connected to an ingress port in an expansion module.
  • In Port: Ingress port on an expansion module. Can be connected to an egress (expansion) port in a controller module or an expansion module.
  • Universal Port: Port that can function as either an egress or ingress port in a controller module or an expansion module.
status string Expander port status.
  • Up: The port is cabled and has an I/O link.
  • Warning: Not all of the port PHYs are up.
  • Error: The port is reporting an error condition.
  • Not Present: The controller module is not installed or is down.
  • Disconnected: Either no I/O link is detected or the port is not cabled.
status-numeric uint32 Numeric equivalents for status values.
  • 0: Up
  • 1: Warning
  • 2: Error
  • 3: Not Present
  • 4: Unknown
  • 6: Disconnected
health string
  • OK
  • Degraded
  • Fault
  • N/A
  • Unknown
health-numeric uint32

Numeric equivalents for health values.

  • 0: OK
  • 1: Degraded
  • 2: Fault
  • 3: Unknown
  • 4: N/A
health-reason string If Health is not OK, the reason for the health state.
health-recommendation string If Health is not OK, the recommended actions to take to resolve the health issue.