The issues that are mentioned in this section are common for all supported operating systems.
Issue ID | Functional area | Description | Workaround |
---|---|---|---|
159410 | Increased workload on the host interrupts communication between iSM and iDRAC | When the workload on the host increases due to intensive task requests by the processor, communication between iSM and iDRAC is temporarily interrupted with the following warning message in the Lifecycle log file: The iDRAC Service Module communication with iDRAC has ended. | The connection automatically resumes and no action is required. |
161262 | ISM0003 event message after replacing the system board | If a USB NIC is enabled after the system board is replaced without restoring the configuration or after the iDRAC is reset to factory settings, you can observe the following ISM0003 event message on operating system log files before starting the communication: The iDRAC Service Module is unable to discover iDRAC from the operating system of the server. | No action is required |
214305 | iDRAC UI launcher fails with OS2iDRAC | iDRAC GUI launcher fails with OS2iDRAC, and
400-Bad Request error is displayed. The iDRAC GUI launcher fails because the
HostHeaderCheck property is enabled on iDRAC and the following features are not functional:
|
To enable the feature, run the command, racadm set iDRAC.WebServer.HostHeaderCheck Disabled To check the status of web server property, run the command, racadm get iDRAC.WebServer.HostHeaderCheck For more information about this property, see, DSA-2021-041: Dell iDRAC8 Security Update for a host header injection vulnerability. |
216788 | RAC804 message logged after performing the iDRACHardReset operation | After performing the iDRACHardReset operation, the following RAC804 message is observed in the operating system logs: The System Configuration Lockdown mode is disabled. | No action is required and no feature is impacted. |
217506 | iDRAC UI is not accessible | The iDRAC UI is not accessible while switching to Federal Information Processing Standards (FIPS) mode on iDRAC. | Restart iDRAC |