Known Issues and resolutions

  • Issue 1

    Description: If a Dell Chassis is configured with only Internet Protocol Version 6 (IPv6) address and is not using the HTTPS default port number (default 443) and was discovered using the Host Name, then the users will not be able to access Chassis Management Controller (CMC) web interface from the Nagios XI console.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: If the default HTTPS port number (port 443) was changed, type https://[<CMC IPv6 address>]:<port number> in the web browser, where <CMC IPv6 address> is the IPv6 address for CMC and <port number> is the HTTPS port number. Please note that you must enclose the IPv6 address in the parenthesis([]).

  • Issue 2

    Description: In "Dell Server Overall Health Status" service, Power Supply Roll up status would be shown as UNKNOWN even if the actual Power supply Roll up status is OK after upgrading iDRAC firmware to 2.30.30.30 or a higher version when Dell server is discovered using WS-MAN. The actual status will be shown correctly once there is any change in the health status of the Power supply.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Launch the respective iDRAC console for the Dell PowerEdge Server host from the Nagios XI to view the Power Supply Roll up status.

  • Issue 3

    Description: In "Dell Chassis I/O Module Status" service, value for "FabricType" is shown incorrectly as "UNKNOWN, for few IO Modules when Dell PowerEdge M1000e chassis is discovered.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e chassis host from the Nagios XI to view the “FabricType”.

  • Issue 4

    Description: In "Dell Chassis power supply status" service, health status for one of the power supply instance which is standby is shown as "UNKNOWN" when Dell chassis is discovered.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI..

    Resolution: Launch the respective chassis console for the Dell PowerEdge M1000e, Dell PowerEdge VRTX, and Dell PowerEdge FX2/FX2s chassis host from the Nagios XI to view the health status of standby power supply.

  • Issue 5

    Description: In "Dell Server Voltage Probe Status", service when one of the instance's actual status is UNKNOWN, that instance will appear as CRITICAL instead of UNKNOWN while monitoring using SNMP protocol with iDRAC firmware version lower than 2.30.30.30.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.

  • Issue 6

    Description: In "Dell Server Voltage Probe Status" service, some of the Voltage instances will be missing when Dell PowerEdge C6320 server is discovered using WS-MAN protocol with iDRAC firmware version lower than 2.30.30.30.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.

  • Issue 7

    Description: In "Dell Server Overall Health Status" service, Power Supply Status is shown as OK instead of UNKNOWN, when Dell PowerEdge T130 or Dell PowerEdge C6320 server is discovered using SNMP protocol, and when Dell PowerEdge DSS1510 server is discovered using SNMP or WS-MAN protocol with iDRAC firmware version lower than 2.30.30.30.

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Upgrade iDRAC firmware version to 2.30.30.30 or above.

  • Issue 8
    Description: When Dell chassis is discovered using IPv6, then the RACADM specific attributes will be displayed as "Not Available" for the following services when RACADM version lower than 8.3.0 is installed:
    • "Dell Chassis Fan Status" - Speed(RPM)
    • "Dell Chassis Power Supply Status" - OutputPower(W), InputVoltage(V), and InputCurrent(A)
    • "Dell Chassis IO Module Status" - Status

    Version affected: Dell OpenManage Plug-in Version 1.0 for Nagios XI.

    Resolution: Install RACADM version 8.3.0 or above in the system where Nagios XI and Dell OpenManage Plug-in is installed