Known Issues

Issue 1(25122):

Description:

In "Dell EMC Chassis I/O Module Status" service, value for "FabricType" is shown incorrectly as "UNKNOWN, for few IO Modules when PowerEdge M1000e chassis is discovered.

Version Affected:

Version 3.1

Issue 2(25121):

Description:

In "Dell EMC Chassis power supply status" service, health status for one of the power supply instance which is standby is shown as "UNKNOWN" when Dell EMC Chassis is discovered.

Version Affected:

Version 3.1

Resolution: Launch the respective chassis console for the PowerEdge M1000e, PowerEdge VRTX, and PowerEdge FX2/FX2s chassis host from the Nagios Core to view the the health status of standby power supply.

Issue 3(178686):

Description:

SNMP traps are not received from the Dell EMC device in the Nagios Core console for Ubuntu setup

Version Affected:

Version 3.1

Issue 4(255091):

Description:

In "Dell EMC Server Overall Health Status" service, Power Supply Status is shown as OK instead of UNKNOWN when DSS 1510 device is discovered using SNMP and WSMan protocol

Version Affected:

Version 3.1

Issue 5(92913):

Description:

In "Dell EMC Network Switch Physical Port Status" service may get timed out in case high number of vlan/virtual ports are configured under monitored Dell EMC Network device.

Version Affected:

Version 3.1

Resolution:

Launch the respective chassis console for the PowerEdge M1000e, PowerEdge VRTX, and PowerEdge FX2/FX2s chassis host from the Nagios Core to view the the health status of standby power supply.

Issue 6(93599):

Description:

In "Dell EMC Server Controller Status" service, an extra instance will be shown only when Dell EMC PowerEdge server is been discovered using RedFish protocol and that device have SATA controller

Version Affected:

Version 3.1

Resolution:

Launch the respective chassis console for the PowerEdge M1000e, PowerEdge VRTX, and PowerEdge FX2/FX2s chassis host from the Nagios Core to view the the health status of standby power supply.

Issue 7(98517):

Description:

Discovery of Dell EMC PowerEdge Server (Rack and Cloud) with firmware versions between 3.00.00.00 and 3.15.15.15 using IPv6 with WSMan or RedFish protocol will fail.

Version Affected:

Version 3.1

Issue 8(155276):

Description:

OMSDK installation may fail with pip version 10.0 and above

Version Affected:

Version 3.1

Resolution:
Follow any one of the below steps:
  • Downgrade pip version to lower than 10.0 and then install omsdk
  • Force install omsdk using: pip install --ignore-installed omsdk

Issue 9(156443):

Description:

ME4 Alert with Event 198 is shown as Normal/Informational instead of Critical.

Version Affected:

Version 3.1


Rate this content