Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC Server Troubleshooting Guide

Troubleshooting a wet system

Steps

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
  2. Remove the system cover.
  3. Remove the following components (if installed) from the system:
    • Power supply unit(s)
    • Optical drive
    • Hard drives
    • Hard drive backplane
    • USB memory key
    • Hard drive tray
    • Cooling shroud
    • Expansion card risers (if installed)
    • Expansion cards
    • Cooling fan assembly (if installed)
    • Cooling fan(s)
    • Memory modules
    • Processor(s) and heat sink(s)
    • Processor and heat sink module
    • System board
    • Mezzanine card
    • Power distribution boards
    • Midplanes
  4. Let the system dry thoroughly for at least 24 hours.
  5. Reinstall the components you removed in step 3 except the expansion cards.
  6. Install the system cover.
  7. Turn on the system and attached peripherals.

    If the problem persists, see the Getting help section.

  8. If the system starts properly, turn off the system, and reinstall all the expansion cards that you removed.
  9. Run the appropriate diagnostic test. For more information, see the Using system diagnostics section.

Next steps

If the tests fail, see the Getting help section.