- Release Summary
Description | SubjectOrganizationalUnit field is not available in GUI or Redfish interface for any security certificates that are stored in iDRAC certificate store. |
Workaround | Use the RACADM command to view the field: racadm sslcertview |
Systems Affected | All systems supported by this release. |
Tracking number | 229355 |
Description | System fans may run in the open loop as DIMM temperature is not available to iDRAC. |
Workaround | N/A |
Systems Affected | PowerEdge XE8545 |
Tracking number | 231580 |
Description | In Lifecycle Controller (LC), updating firmware through catalog update using NFS share fails with an error "Invalid catalog file". |
Workaround | Ensure that you add the catalog file name and extension in the Source NFS path, or update using any other network shares. |
Systems Affected | All systems supported by this release. |
Tracking number | 204784 |
Description | In iDRAC GUI Cooling page, Temperature probe name of GPU displays "System Board SLOTx Temp" instead of "System Board GPUx Temp". |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 214506 |
Description | After performing a PSU firmware update through DUP method, only one sled powers on automatically while others remain powered off. |
Workaround | Use iDRAC GUI to power on the remaining sleds. |
Systems Affected | PowerEdge C6420 |
Tracking number | 209713 |
Description | The property ManagedSystemSize may display an incorrect value in the iDRAC system inventory page. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 212710 |
Description | After an iDRAC firmware update, iDRAC GUI or remote RACADM may fail to display information about the second PSU. |
Workaround | Perform an iDRAC reset. |
Systems Affected | All systems supported by this release. |
Tracking number | 207006 |
Description | Updating iDRAC firmware to version 4.40.00.00 or later may cause the vFlash partitions to detach on first boot after the update. |
Workaround | Reattach the detached vFlash partitions through any iDRAC interfaces after the first boot. |
Systems Affected | All systems supported by this release. |
Tracking number | 194849 |
Description | After updating backplane firmware to a newer version and then updating it back to a previous version from host OS, the backplane information is not displayed while trying to apply the firmware Rollback. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184368 |
Description | iDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings. |
Workaround | Configure NTP settings and export the Server configuration Profile. Import the Server configuration profile with NTP and manually configure SNTP settings. |
Systems Affected | All systems supported by this release. |
Tracking number | 181069 |
Description | While the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time. |
Workaround | N/A |
Systems Affected | All PowerEdge Rxxx5/Cxxx5 systems supported by this release. |
Tracking number | 183347 |