iDRAC9 Version 5.10.30.00 Release Notes

PDF

Monitoring and alerting

Table 1. CPU temperature greater than threshold limit Lifecycle (LC) logs may display "CPU temperature is greater than the upper critical threshold" during a system-warm reboot.
Description Lifecycle (LC) logs may display "CPU temperature is greater than the upper critical threshold" during a system-warm reboot.
Workaround A deassertion event is logged automatically after a few seconds that display that the temperature is within range.
Systems Affected PowerEdge R7525 and PowerEdge R6525
Tracking number 228837
Table 2. SEL reports fixed PSU errors SEL may continuously report PSU-related errors even after the error is fixed.
Description SEL may continuously report PSU-related errors even after the error is fixed.
Workaround N/A
Systems Affected All 15th generation PowerEdge systems supported by this release.
Tracking number 228719
Table 3. PR7 messages for all devices logged in LCDuring an AC power cycle stress, random PR7 (New device detected) messages may get logged for devices such as CPU, DIMM, NICs, Storage Cards, and so on in the Lifecycle controller (LC) logs even though no actual hardware-related change was performed. There is no impact on device functionality.
Description During an AC power cycle stress, random PR7 (New device detected) messages may get logged for devices such as CPU, DIMM, NICs, Storage Cards, and so on in the Lifecycle-Controller (LC) logs even though no actual hardware-related change was performed. There is no impact on device functionality.
Workaround N/A
Systems Affected PowerEdge R740, PowerEdge R640, PowerEdge R840, and PowerEdge T640
Tracking number 208278
Table 4. SCP import failing Importing SCP file that was exported from a system with iDRAC version 5.00.15.00 to a system with iDRAC version 5.00.20.00 or later versions may fail.
Description Importing SCP file that was exported from a system with iDRAC version 5.00.15.00 to a system with iDRAC version 5.00.20.00 or later versions may fail.
Workaround Update the iDRAC version of the system exporting SCP file to iDRAC version 5.00.20.00 and then try exporting the file again.
Systems Affected All systems supported by this release.
Tracking number 213900
Table 5. SEL events may not be correctly displayed in the earlier versions of iDRACNew SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Description New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Workaround N/A
Systems Affected All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release.
Tracking number 186384
Table 6. PR1 & PR10 Lifecycle logs displayed during Retire and Repurpose operation PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Description PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 186119
Table 7. SupportAssist collection failingUnable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.
Description Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.
Workaround Generate SupportAssist collection with only system information option checked.
Systems Affected All systems supported by this release.
Tracking number 159527
Table 8. After a warm reboot, LC logs display Disk Inserted After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Description After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 144819 and 141414
Table 9. Repetitive PR7 messages related to PSU in LC logs after a system erase operation When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Description When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 129440