iDRAC9 Version 5.10.30.00 Release Notes

PDF

iDRAC firmware

  1. PowerEdge servers that shipped with iDRAC9 4.40.40.00 or later versions require stepped downgrades before rolling back to version 4.40.00.00 or older firmware. The iDRAC9 must be downgraded to 4.40.10.00 and then to the older firmware.
  2. In Firmware Rollback page, the component names may vary in iDRAC GUI and Lifecycle Controller(LC) GUI.
  3. Due to known limitations in OpenSource (SFCB), query filtering with long integers and lengthy strings may not work as expected.
  4. LC can import and view an iDRAC license but cannot export or delete the iDRAC license. The iDRAC license can be deleted from iDRAC web interface.
  5. The iSCSI offload attribute can be enabled only on two of the four available ports. If a card, which has this attribute that is enabled on two of its ports, is replaced with another card that has the attribute that is enabled on the other two ports, an error occurs. The firmware does not allow the attribute to be set because it is already set on the other two ports.
  6. The "Discovered Servers" view of Group Manager may not show available iDRACs as available to onboard. Verify that the iDRACs are on the same link local network and not separated by a router. If they are still not visible, reset the Group Manager's controlling iDRAC.
    1. Open Group Manager on one of the member iDRACs.
    2. In the search box, type the controlling system's Service Tag.
    3. Double-click the iDRAC that matches the search results and go to iDRAC Settings -> Diagnostics.
    4. Select Reset iDRAC.

    When iDRAC fully restarts, Group Manager should see the new iDRAC.

  7. If Emulex LightPulse LPe31002-M6-D and Emulex LightPulse LPe35002-M2 FC adapters are configured to boot from FC storage arrays using VAM method in iDRAC, then a maximum of two boot target arrays can be configured instead of eight.
  8. During import server profile operation, if the image filename is "Backup.img", operation may fail. To avoid this failure, change the filename.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\