Storage and storage controllers

Table 1. Updated HBA controller version missing After an HBA controller firmware is updated through OS, iDRAC does not display the updated controller firmware version.
Description HBA controller firmware version that was updated through OS is not displayed in iDRAC.
Workaround Perform an iDRAC reset or cold boot the system.
Systems Affected All systems supported by this release with HBA 330 or HBA 355 controller.
Tracking number 236357
Table 2. Max Capable Speed reported as Unknown Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC.
Description Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 230290
Table 3. SCP import job fails to secure the drive Secure erase and enable security operation on a secured drive using Server Configure Profile (SCP) import operation fails if Auto Secure option is disabled.
Description Secure erase and enable security operation on a secured drive using Server Configure Profile (SCP) import operation fails if Auto Secure option is disabled.
Workaround Enable Auto Secure option before the import operation or secure the drive using any iDRAC interfaces after import operation.
Systems Affected All systems supported by this release.
Tracking number 213729
Table 4. LC logs display incorrect version change for disks After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Description After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 197049
Table 5. Deleting VD creates pending operation with empty data When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Description When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Workaround To successfully delete the VD and add to pending operations, perform the following steps:
  1. Select the Configuration option in iDRAC GUI
  2. Select Storage Configuration, then select the Controller and click Apply now.
Systems Affected All systems supported by this release.
Tracking number 184393

Rate this content